Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry

Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry
在线阅读 下载PDF
导出
摘要 Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine. Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS) in positive electrospray ionization mode. Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step. Separation was achieved on an Acquity UPLC SS T3 column. The mobile phase was acetonitrile and water containing 0. 2%(v/v)formic acid. The mass spectrometer was operated in multiple reaction monitoring mode. Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20 μg/L. The accuracy(internal standard corrected) ranged from 92% to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15% for all five analytes. The RSDs within-laboratory reproducibility was less than 26%. The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3. 1-6. 1 μg/L and 4. 0-7. 4 μg/L,respectively. The CCα and CCβ values were below the recommended concentration,which was set at 10 μg/L. The results show that the described method is suitable for the direct detection of TSs in bovine urine. This method can also be used to determine TSs in porcine urine.
出处 《色谱》 CAS CSCD 北大核心 2017年第10期1048-1054,共7页 Chinese Journal of Chromatography
关键词 ultra-high performance liquid chromatography-tandem mass SPECTROMETRY (UHPLC-MS/MS) thyreostats (TSs) URINE ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS) thyreostats(TSs) urine
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部