期刊文献+

三向锥度螺纹髋臼定位器临床应用(附10例报告) 被引量:1

CLINICAL REPORT OF ARTIFICIAL ACETABULUM WITH TRIPHASE CONICAL SCREW INSTRUMENTS
暂未订购
导出
摘要 本套器械系为了解决目前国际上尚未解决的人工髓臼三个方向一次性准确定位问题及人工髋臼固定欠佳问题.它由髋臼铰刀、锥度螺纹铣头、陶臼置入器及定向手术架四部分组成.其核心构件为一件铣头,它对陶臼的七个系列(φ:50、52、55、57、60、63、65mm)皆能通用.并能一次成型内螺纹.用于尸髓成型54次,成功50次(92.6%).临床手术10次,全部成功.本器械以机械固定方式安装陶臼;代替用粘固剂固定,无疑提供了一套先进、高效手段,并能提高人工髋关节置换手术疗效. In 1982, We reported the reasearch of whole-ceramic artificial hip joint. In this paper, a method is established for implanting direction and fixation of ceramic artificial acetabulum. The fixation can be active mechanical fixation by using three directional conical screw instruments of acetabulum which have been invented and applied in clinical by us.This study presents a discouraging results.Of a total of 54 cadaver acetabulum 50 were successful and in all of 10 patients whole-ceramic acetabula had been implanted satisfactorily by using our instruments
出处 《重庆医科大学学报》 CAS CSCD 1991年第3期238-241,共4页 Journal of Chongqing Medical University
关键词 髋臼定位器 人工髋臼 三向手术架 Artificial acetabulum Conical screw seamer Triphase stand of operation
  • 相关文献

同被引文献39

  • 1王海涛.髋臼帽定位器的研制[J].骨与关节损伤杂志,2004,19(8):527-527. 被引量:10
  • 2Krushell R J, Burke DW, Harris WH. Elevated-rim acetabular components: Effect on range of motion and stability in total hip arthroplasty. J Arthroplasty, 1991, 6 (Suppl): 53-58.
  • 3Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocation after total hip-replacement arthroplasties. J Bone Joint Surg(Am), 1978, 60: 217-220.
  • 4Morrey BF. Difficult complications after hip joint replacement:Dislocation. Clin Orthop, 1997, (344): 179-187.
  • 5Paterno SA, Lachiewicz PF, Kelley SS. The influence of patient-related factors and the position of the acetabular component on the rate of dislocation after total hip replacement. J Bone Joint Surg(Am), 1997, 79: 1202-1210.
  • 6Sultan PG, Tan V, Lai M, Garino JP. Independent contribution of elevated-rim acetabular liner and femoral head size to the stability of total hip implants. J Arthroplasty, 2002, 17:289-292.
  • 7Noble PC, Sugano N, Johnston JD, Thompson MT, Conditt MA, Engh CA Sr, Mathis KB. Computer simulation: How can it help the surgeon optimize implant position? Clin Orthop,2003, (417): 242-252.
  • 8Knight JL, Atwater RD. Preoperative planning for total hip arthroplasty: Quantitating its utility and precision. J Arthroplasty, 1992, 7 (Suppl): 403-409.
  • 9Mc Auley JP, Ridgeway SR. Preoperative planning to prevent dislocation of the hip. Orthop Clin North Am, 2001, 32:579-586.
  • 10Sugano N, Ohzono K, Nishii T, Haraguchi K, Sakai T, Ochi T. Computed tomography-based computer preoperative planning for total hip arthroplasty. Comput Aided Surg, 1998, 3:320-324.

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部