摘要
对小型水电站发电机组控制及励磁调节系统进行了设计计算、设备选型整定。分析了小型水电站发电机端电压过高的原因 ,并提出了解决办法 。
The design calculation of the generator set control and field adjusting system as well as the equipment lectotype setting for small water power station are performed. The cause of voltage overtension at generator end in small water power station is analyzed,and the solution method is proposed, which has been proven workable by practice.
出处
《电气传动自动化》
2002年第5期24-25,13,共3页
Electric Drive Automation
关键词
小型水电站
发电机组
励磁调节系统
hydroelectric power station
generator set control
field adjusting