摘要 目的探讨一种腔静脉滤器回收方法的可行性及初步经验。方法 2015年1月~2017年10月,对39例下肢深静脉血栓形成置入可回收腔静脉滤器者,采用一次性活检钳联合可调弯鞘进行腔静脉滤器的回收。结果 39例均成功回收滤器。射线曝光下回收滤器的操作时间为1分08秒~12分57秒,平均5分58秒,回收滤器均结构完整,无折损断裂,术中术后无死亡及血管损伤、出血、肺动脉栓塞等并发症。随访6~28个月,平均12个月,无相关并发症发生。结论采用一次性活检钳联合可调弯鞘回收腔静脉滤器安全,可行。 Objective To investigate the feasibility of a new method for recovering inferior vena eava (IVC) filters. Methods From January 2015 to October 2017, the combination of disposable biopsy forceps and adjustable curved sheaths was used to recover IVC filters in 39 patients implanted with recoverable IVC filters for lower-extremity deep venous thrombosis (DVT). Results The filters were successfully recovered in all the 39 patients. The operation time of filter recovery under radiographic exposure was from 1 minute 8 seconds to 12 minutes 57 seconds (mean, 5 minutes 58 seconds). The recovered filters remained intact without fractures. No intraor post-operative deaths or complications such as vascular injuries, bleeding or pulmonary artery embolism occurred. No relevant complications were observed during follow-ups for 6 - 28 months ( mean, 12 months). Conclusion The combination of disposable biopsy forceps and catheters with adjustable curved sheaths for recovering IVC filters is safe and feasible.
作者 焦强 李学锋 武欣 王清霖 沙斐 曹娟 柴政 Jiao Qiang;Li Xuefeng;Wu Xin(Department of Vascular Surgery,Wang Jing Hospital of CACMS,Beijing 100102,China)
出处 《中国微创外科杂志》 CSCD 北大核心 2018年第11期1015-1017,共3页 Chinese Journal of Minimally Invasive Surgery
关键词 可调弯鞘 腔静脉滤器 滤器回收 深静脉血栓 一次性活组织取样钳 Adjustable curved sheath Inferior vena eava filter Filter recovery Deep vein thrombosis Disposable biopsy forceps
  • 相关文献

参考文献4

二级参考文献58

  • 1翟仁友,戴定可.下腔静脉滤器置入术预防致死性肺动脉栓塞(附三例分析)[J].中华放射学杂志,1995,29(7):448-451. 被引量:57
  • 2鲍姆,徐克,滕皋军,译.Abrams介入放射学[M].第二版.北京:人民卫生出版社,2010:1035-1047.
  • 3Savader SJ,Trerotola SO.Venous interventional radiology with clinical perspectives[M].2 nd.ed.New York.Sluttgart:Thieme,2000:511-525.
  • 4Kinney TB.Updata on inferior vena cava filters[J].J Vasc Interv Radiol,2003,14:425-440.
  • 5Asch MR.Initial experience in humans with a new retrievable inferior vena cava filter[J].Radiology,2002,225:835-844.
  • 6Onat L,Ganiyusufoglu AK,Mutlu A,et al.OptEase and TrapEase vena cava filters:a single-center experience in 258 patients[J].Cardiovasc Intervent Radiol,2009,32:992-997.
  • 7Millward SF,Grassi CJ,Kinney TB,et al.Reporting standards for inferior vena caval filter placement and patient follow up:supplement for temporary and retrievable/optional filters[J].J Vasc Interv Radiol,2005,16:441-443.
  • 8Rosenthal D,Wellons ED,Hancock SM,et al.Retrieva-bility of the Gunther Tulip vena cava filter after dwell times longer than 180 days in patients with multiple trauma[J].J Endovasc Ther,2007,14:406-410.
  • 9The PREPIC Study Group.Eight-year follow-up of patients with permanent vena cava filters in the prevention of pulmonary embolism:the PREPIC randomized study[J].Circulation,2005,112:416-422.
  • 10徐克 周玉斌.DVT及其致命性肺动脉栓塞介入性防治方法的研究.中华放射学杂志,2003,37:81-86.