期刊文献+

噪声免疫腔增强光外差分子光谱技术综述 被引量:5

Review on Noise Immune Cavity Enhanced Optical Heterodyne Molecular Spectroscopy
原文传递
导出
摘要 噪声免疫腔增强光外差分子光谱技术(NICE-OHMS)结合了频率调制光谱和腔增强吸收光谱两种技术,是目前探测灵敏度最高的激光吸收光谱技术。首先介绍NICE-OHMS技术的基本原理和实现过程,然后概括其发展现状,重点介绍各个课题组采用的激光源、腔的精细度等关键参数,及其对探测灵敏度的影响,最后提出限制NICE-OHMS技术探测灵敏度的主要因素及其解决方案。 Noise immune cavity enhanced optical heterodyne molecular spectroscopy(NICE-OHMS)can provide the highest detection sensitivity in the field of laser absorption spectroscopy by combining two techniques of frequency modulation spectroscopy and cavity enhanced absorption spectroscopy.The principle and implementation process of NICE-OHMS are introduced.Then,the historical development of NICE-OHMS is overviewed,which mainly focuses on the key parameters,such as the applied laser source and the cavity finesse used by each research group and their obtained detection sensitivity.Finally,the limitation factors of the detection sensitivity of NICE-OHMS are analyzed,and the related solutions are provided.
作者 马维光 周月婷 赵刚 贾梦源 刘建鑫 郭松杰 董磊 张雷 尹王保 肖连团 Axner Ove 贾锁堂 Ma Weiguang1,2, Zhou Yueting1,2, Zhao Gang1,2, Jia Mengyuan1,2, Liu Jianxin1,2, Guo Songjie1,2 Dong Lei1,2, Zhang Lei1,2, Yin Wangbao1,2, Xiao Liantuan1,2, Axner Ove3, Jia Suotang1,2(1. State Key Laboratory of Quantum Optics & Quantum Optics Devices, Institute of Laser Spectroscopy, Shanxi University, Taiyuan, Shanxi 030006, China; 2 Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan, Shanxi 030006, China ; 3Department of Physics, Umedt University, Umea, SE-901 87, Swede)
出处 《中国激光》 EI CAS CSCD 北大核心 2018年第9期89-99,共11页 Chinese Journal of Lasers
基金 国家重点研发计划(2017YFA0304203) 国家自然科学基金(61675122,11704236,61475093,61775125) 山西省回国留学人员科研资助项目(2017-016)
关键词 光谱学 频率调制 腔增强 痕量气体检测 探测灵敏度 spectroscopy frequency modulation cavity enhancement trace gas detection detection sensitivity
  • 相关文献

参考文献2

二级参考文献19

  • 1陈东,刘文清,张玉钧,刘建国,魏庆农,陈玖英,阚瑞峰,王敏,崔益本,方武,张永明,祝玉泉.可调谐半导体激光光谱火灾气体探测系统[J].中国激光,2006,33(11):1552-1556. 被引量:27
  • 2宋晓辉,海中天.接触燃烧式气敏传感器的研制[J].计量技术,2007(8):76-78. 被引量:7
  • 3V. Nagali, S. I. Chou, D. S. Baer et al.. Tunable diode-laser absorption measurements of methane at elevated temperatures [J]. Appl. Opt., 1996, 35(21): 4026-4032.
  • 4Ma Weiguang, Yin Wangbao, Dong Lei et al.. High-sensitivity detection of methane near 6106 cm-1 using tunable external-cavity diode laser [J]. Japanese Journal of Applied Physics, 2005, 44(4A): 1961-1965.
  • 5G. C. Bjrklund. Frequency-modulation spectroscopy: a new method for measuring weak absorptions and dispersions [J]. Opt. Lett., 1980, 5(1): 15-17.
  • 6B. A. Paldus, A. A. Kachanov. An historical overview of cavity-enhanced methods [J]. Canadian J. Physics, 2005, 83(10): 975-999.
  • 7A. Foltynowicz, W. G. Ma, F. M. Schmidt et al.. Doppler broadened noise immune cavity enhanced optical heterodyne molecular spectrometry signals from optically saturated transitions under low pressure conditions [J]. J. Opt. Soc. Am. B, 2008, 25(7): 1156-1165.
  • 8Li Liufeng, Liu Fang, Wang Chun et al.. Measurement and control of residual amplitude modulation in optical phase modulation [J]. Review Scientific Instruments, 2012, 83(043111): 1-10.
  • 9Isak Silander, Patrick Ehlers, Junyang Wang et al.. Frequency modulation background signals from fiber-based electro optic modulators are caused by crosstalk [J]. Journal of Optical Society of America B, 2012, 29(5): 916-923.
  • 10N. C. Wong, J. L. Hall. Servo control of amplitude modulation in frequency modulation spectroscopy: demonstration of shot-noise-limited detection [J]. Journal of Optical Society of America B, 1985, 2(9): 1527-1533.

共引文献6

同被引文献68

引证文献5

二级引证文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部