摘要 以热舒适状态下的假人为研究对象,进行了人体典型裸露部位(脸部和头部)与环境换热特性的实验研究,分析了在不同送风温度、风量和气流组织下的对流换热量和辐射换热量的范围及其比值。结果表明:在稳态热舒适状态下,人体脸部和头部对流换热量的变化范围为6~93 W/m^2,辐射换热量变化范围为26~60 W/m^2,辐射与对流换热量的比值变化范围为0.47~6.65;针对不同气流组织形式,个性化送风以对流换热为主,而混合送风和座椅送风均以辐射换热为主。 Taking the manikin in thermal comfort condition as a study object, develops the heat transfer characteristic experiments between the typical exposed human body parts and the surrounding environment, such as head and face. Analyses the value ranges and the ratios of the radiation heat transfer to the convection heat transfer at different air supply temperature, air volume and air distributions. The results show that when the head and face are in steady thermal comfort state, their convection heat transfer and radiation heat transfer are 6 to 93 W/m^2 and 26 to 60 W/m^2 respectively, and the ratio of radiation heat transfer to convection heat transfer is 0.47 to 6.65. According to different air distributions, the personalized ventilation is dominated by the convection heat transfer while the mixed air distribution and the seat ventilation depend on the radiation heat transfer.
作者 王丽慧 刘畅 张建舜 孔盟 邹学成 白芯慧 Wang Lihui;Liu Chang;Zhang Jianshun;Kong Meng;Zou Xuecheng;Bai Xinhui(University of Shanghai for Science and Technology, Shanghai, Chin)
出处 《暖通空调》 2018年第6期97-102,共6页 Heating Ventilating & Air Conditioning
基金 国家自然科学基金资助项目(编号:50908147)
关键词 裸露部位 对流换热 辐射换热 分离实验 送风温度 送风量 气流组织 exposed part convection heat transfer radiation heat transfer separation experiment supply air temperature supply air volume air distribution
  • 相关文献

参考文献5

二级参考文献41

  • 1国家质量技术监督局.GB/T18049-2000中等热环境PMV和PPD指数的测定及热舒适条件的规定[S].北京:中国标准出版社,2001.
  • 2赵荣义,范存养,薛殿华,等.空气调节[M]3版.北京:中国建筑工业出版社,2001.
  • 3Olesen B W. Possibilities and limitations of radiant floor cooling [G]//ASHRAE Trans, 1997, 103(1) : 42- 48.
  • 4Olesen B W, Michel E. Heat exchange coefficient between floor surface and space by floor cooling-- Theory or a question of definition [G]//ASHRAE Trans, 2000, 106(1): 684-694.
  • 5卢军,陈金花,高殿策,丁豪.住宅用地板辐射供冷系统的实验分析[J].暖通空调,2007,37(12):20-24. 被引量:7
  • 6Davie M G. On the basis of'environmental procedures [J]. Building and Environment, 1978, 13(1):29-46.
  • 7Walton G N. A new algorithm for radiant interchange in room loads calculations [ G] // ASHRAE Trans, 1980, 86(2):190-208.
  • 8Maloney D M, Pedersen C O, Witte M J. Development of a radiant heating systems model for blast [ G]// ASHRAE Trans, 1988, 94(1) :1795-1808.
  • 9Zmeureanu R, Fazio P P, Haghighat F. Thermal performance of radiant heating panels [G] /// ASHRAE Trans, 1988, 94(1) : 13-27.
  • 10Athienitis A K, Shou J G. Control of radiant heating based on the operative temperature[G]//ASHRAE Trans, 1991, 97(2) :787- 794.

共引文献48

同被引文献34

引证文献5

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部