混凝土抗渗性能现场检测技术试验研究 被引量:10

Experimental Study on On-site Testing Technology of Concrete Permeability
在线阅读 下载PDF
导出
摘要 混凝土渗透性是决定混凝土耐久性的重要因素,是我国工程建设质量见证取样强制控制的检测项目,但一直缺乏有效的现场检测方法,只能通过送样试块在试验室试验控制,与实际工程质量有较大偏差。本文利用Torrent透气法(一种新型混凝土渗透性检测技术),与传统的水压渗透试验方法进行对比试验研究,建立了Torrent透气法最大压力差ΔP_(max)与渗水高度法渗透深度L_w的相互关系,论证了Torrent透气法应用于混凝土抗渗性现场无损检测的可行性。 The concrete permeability is an important factor to the durability of concrete and is the compulsory control testing project of the witness sampling in China, but it lacks effective on-site detection method, which must be tested in laboratory, thus there is a large deviation with the actual project. Torrent ventilation method is used to be compared with the experimental research laboratory pressure permeation test method, the relationship between maximum differential pressure △pmax, of Torrent breathable and penetration depth Lw of water penetration height method are established, which has demonstrated the feasibility of Torrent ventilation method applied on messuring the permeability of concrete.
出处 《混凝土与水泥制品》 北大核心 2018年第3期82-85,共4页 China Concrete and Cement Products
关键词 混凝土渗透性 Torrent透气法 现场检测 Concrete permeability Torrent centilation method On-site testing
  • 相关文献

参考文献4

二级参考文献60

  • 1李淑进,赵铁军.混凝土的渗透性与耐久性[J].海岸工程,2001,20(2):68-72. 被引量:34
  • 2练波.从混凝土的渗透性预测混凝土的耐久性[J].广东建材,2002,25(1):43-44. 被引量:5
  • 3孟振全,吴振琏.表面渗透性对混凝土耐久性的影响[J].工业建筑,1994,24(5):46-49. 被引量:12
  • 4牛荻涛,陈亦奇,于澍.混凝土结构的碳化模式与碳化寿命分析[J].西安建筑科技大学学报(自然科学版),1995,27(4):365-369. 被引量:91
  • 5[1]How to make today's concrete durable for tomorrow[R]. The instruction of Civil Engineers.London. 1985.
  • 6[3]吴中伟.论水泥混凝土耐久性研究的思路与方法[R].中国建材科学研究院报告,1997.
  • 7[9]Shilstone J M. Proceedings on concrete technology: Past, present and future[R]. USA. ACI sp-144, 1994.
  • 8KOLLEK J J.The determination of the permeability of concrete to oxygen by the cembureau method-a recommendation[J].Ma-terials and Structures, 1989(22):225-230.
  • 9KROPP J,HILSDORF H K.RILEM report 12:performance criteria for concrete durability[R].Germany:E&FN SPON, 1995.
  • 10TORRENT R,FRENZER G.A methord for the rapid determination of the coefficient of permeability of the "covercrete"[J].International Symposium Non-Destructive Testing in Civil Engineering (NDT-CE)26.-28.09. 1995.