期刊文献+

夜间辐射制冷在地源热泵中的应用 被引量:4

Application of night radiant cooling to ground-source heat pumps
在线阅读 下载PDF
导出
摘要 针对地源热泵技术用于冷负荷占优型建筑物时地下热积累导致的性能下降问题,提出了应用夜间辐射散热器作为辅助散热器的新型地源热泵复合系统。设计了夜间辐射散热器,构建了夜间辐射散热器及新型复合系统的解析解模型,并编写了相应的系统运行模拟程序。以香港某小型住宅为例,设计了新型地源热泵复合系统,并对其运行性能及能耗进行了模拟计算。依据计算结果分析了夜间辐射制冷在地源热泵技术中应用的可行性。 Aiming at the performance degradation of ground-source heat pump technology used in cooling load dominant buildings, puts forward a new ground-source heat pump hybrid system with auxiliary night radiators. Designs a night radiator, constructs an analytical solution model of night radiator and new hybrid system, and compiles the corresponding system operating simulation program. Taking a small residential house in Hong Kong as an example, designs a new type of ground-source heat pump hybrid system, and simulates its operating performance and energy consumption. Based on the calculation results, analyses the feasibility of the application of night radiant cooling technology to the ground-source heat pump.
出处 《暖通空调》 2018年第2期73-80,共8页 Heating Ventilating & Air Conditioning
基金 山东省自然科学基金项目(编号:BS2015NJ016) 山东省绿色建筑协同创新中心团队建设基金项目(编号:LSXT201502) 山东建筑大学博士基金项目(编号:XNBS1222) 山东省科技厅研究专项项目(编号:2013SJGZ15) 国家自然科学基金项目(编号:61374187)
关键词 夜间辐射制冷 地源热泵复合系统 冷负荷占优型建筑 辅助散热器 地埋管 换热器 night radiant cooling, ground-source heat pump hybrid system, cooling load dominant building, auxiliary radiator, ground heat exchanger
  • 相关文献

参考文献3

二级参考文献14

  • 1Yu M Z, Diao N R, Fang Z H. Apilot project of the closed-loop ground-source heat pump system in China [A] . Proceeding of 7thIEA Conference on Heat Pumping Technologies [ C ] . Beijing: China Architecture and Building Press, 2002.356-364.
  • 2Halozan H. Heat pumps and the environment [A] .Proceeding of 7th IEA Conference on Heat Pumping Technologies [ C ] . Beijing: China Architecture and Building Press, 2002.61-65.
  • 3Rybach L, Sanner B. Ground-source heat pump systems: the European experience [J] . Geo-Heat Center Quarterly Bulletin. Klamath Falls. Oreg. Oregon Institute of Technology. 2000, 21(1): 16-26.
  • 4Mei V C, Emerson C J. New approach for analysis of ground-coil design for applied heat pump systems [J] .ASHRAE Trans, 1985, 91, Part 2B: 1216-1224.
  • 5Yavuzturk, C, Spitler J D, Rees S J. A transient twodimensional finite volume modal for the simulation of vertical U-tube ground heat exchangers [ J ] .ASHRAE Trans, 1999, 105(2): 465-474.
  • 6Gu Y, O'Neal D L. Development of an equivalent diameter expression for vertical U-tubes used in groundcoupled heat pumps [J] . ASHRAE Trans, 1998, 104(2): 347-355.
  • 7Hellstrom G. Ground heat storage: thermal analysis of duct storage systems [D] . Department of Mathematical Physics, University of Lund, Sweden. 1991.
  • 8Diao N R, Cui P, Fang Z H. The thermal resistance in a borehole of geothermal heat exchanger [A] . Heat Transfer 2002, Proc. 12th International Heat Transfer Conference [C] .France, 2002: 339-343.
  • 9Zeng H Y, Diao N R, Fang Z H. Heat transfer analysis of boreholes in vertical ground heat exchangers[J]. International Journal of Heat and Mass Transfer, 2003,46(23): 4467-4481.
  • 10钱滨江.简明传热手册[M].北京:高等教育出版社,1984..