摘要
为使M701F4燃气-蒸汽联合循环发电机组在高负荷运行时获得最大的经济效益,将机组置于几种不同控制模式下稳定运行,对发电气耗、厂用电等数据进行统计、分析,结合一次调频的要求与考核,对温控和非温控模式下的综合经济效益进行量化对比,得出转速控制(贴近温控)模式的最优运行方式,可为同类型机组运行方式的选择提供参考。
In order to make the M701F4 gas-steam combined cycle power generation unit in high load operation achieve maximum economic benefits,the unit stable operation under different control mode,the electric consumption,such as auxiliary power data statistics,analysis,combined with the primary frequency control modulation requirements and testing,the temperature control and temperature control mode of the comprehensive economic benefits of quantitative comparison,draw speed control(close to the temperature control) model of the optimal operation mode,can provide a reference for the choice of the same type unit operation mode.
出处
《华电技术》
CAS
2017年第12期21-23,43,共4页
HUADIAN TECHNOLOGY
关键词
M701F4燃气轮机
发电气耗
转速控制模式
温度控制模式
一次调频
M701 F4 gas turbine
electricity consumption
speed control mode
temperature control mode
primary frequency modulation