摘要
二苯并呋喃加氢产物有环己基苯、联苯、邻苯基苯酚,建立四种组分含量的毛细管气相色谱测定方法,采用内标法分析组分。毛细管柱为HP-5、氢火焰离子化验检测器和程序升温,以环己烷为溶剂,萘为内标物对上述组分进行测定。结果表明,加氢产物中各组分能很好的分离并且分析时间不超过15 min。这种方法更加精准、操作简便,相对标准偏差为0.57%~2.82%。
The hydrogenation products of dibenzofuran include cyclohexyl benzene,biphenyl,o-phenyl phenol. In this paper, determination method of the four components content by capillary gas chromatography was established; the components were analyzed by the internal standard method. Type of apillary column was HP-5;FID and TPD were used,cyclohexane was used as solvent, naphthalene was used as internal standard. The results show that the components of the hydrogenation product can be well separated and the analysis time is less than 15 min. This method is more accurate, easy to operate; the relative standard deviation is 0.57%~2.82%.
出处
《当代化工》
CAS
2017年第9期1940-1943,共4页
Contemporary Chemical Industry
基金
河北省重点科技计划项目
氧芴的综合利用-氧芴加氢裂化反应研究
项目号:16211403D
关键词
二苯并呋喃
环己基
联苯
邻苯基苯酚
气相色谱
内标法
Dibenzofuram Cyclohexyl benzene: Biphenyl
O-phenyl phenol: Gas chromatography
Internal standardmethod