期刊文献+

荧光标记法在评价及改进医院环境清洁质量中的应用 被引量:21

Application of fluorescence marker in assessment and improvement of environmental cleaning quality of hospitals
原文传递
导出
摘要 目的研究应用荧光标记法评价及改进医院环境清洁质量,进而降低医疗保健相关感染(HAI)。方法应用荧光标记法对医院病区床单元及医疗办公设备高频接触物表进行干预前后清洁质量的评价。结果中度、高度和极高度危险区域高频接触物表(包括床单元及医疗办公设备)干预前共做荧光标记1681处,合格1096处,清洁合格率65.20%;干预后共做荧光标记1683处,合格1347处,清洁合格率80.04%,干预前后比较,差异有统计学意义(χ~2=93.106,P<0.001);床单元高频接触物表干预前后比较,床头桌、床头、床尾、摇把手干预前后差异有统计学意义(P<0.05),床栏、设备带干预前后差异无统计学意义,医疗办公设备高频接触物表清洁合格率干预前后比较,治疗室操作台面、综合治疗车、换药车/服药车、电脑键盘、护士站及医生办公室电话、监护仪和输液泵干预前后差异有统计学意义(P<0.05);换药室操作台面干预前后差异无统计学意义。结论应用荧光标记法能快速、直观评价及考核清洁人员是否按规范进行环境物表的清洁,及时发现医院感染风险,教育培训有针对性,是医院感染控制及环境清洁质量改进的有效管理工具。 OBJECTIVE To apply the fluorescence marker in assessment and improvement of environmental cleaning quality of hospitals so as to reduce the incidence of healthcare-associated infections(HAI).METHODS The cleaning quality of bed units and surfaces of high-frequency contact objects was evaluated by using fluorescence marker before and after the intervention.RESULTS Totally 1681 fluorescence markers were made for the surfaces of highfrequency contact objects in medium,high and extremely high risk zones before the intervention,including the bed units and office equipments,of which 1096 were qualified,with the qualified rate of cleaning 65.20% .Totally1683 fluorescence markers were made after the intervention,of which 1347 were qualified,with the qualified rate of cleaning 80.04% ,and there was significant difference before and after the intervention(χ^2=93.106,P〈0.001).There was significant difference in the surfaces of high-frequency contact objects bed units before and after the intervention(P〈0.05);there was significant difference in the bedside table,bed head,bed tail,or shake handles before and after the intervention(P〈0.05),there was no significant difference in the bedrails or equipment belts before and after the intervention.There was significant difference in the qualified rate of cleaning of surfaces of high-frequency contact office equipments before and after the intervention(P〈0.05);there was significant difference in the operation tables of treatment rooms,comprehensive treatment vehicles,dressing change carts/drug carriers,computer keyboards,nursing stations,telephones in doctors′offices,monitors,or infusion pumps before and after the intervention(P〈0.05);there was no significant difference in the operation tables of dressing change rooms before and after the intervention.CONCLUSIONThe fluorescence marker may facilitate the rapid,intuitive evaluation and assessment of the cleanliness of the environmental objects surfaces,find out the risk factors for nosocomial infection and conduct targeted training,it is an effective management tool for the control of nosocomial infection and improvement of environmental cleaning quality.
出处 《中华医院感染学杂志》 CAS CSCD 北大核心 2017年第18期4261-4264,共4页 Chinese Journal of Nosocomiology
基金 济宁医学院附属医院"苗圃计划"科研基金资助项目(MP-2016-005)
关键词 荧光标记法 医院感染 高频接触物表 风险评估 评价 Fluorescence maker Nosocomial infection High-frequency contact surface Risk assessment Evaluation
  • 相关文献

参考文献4

二级参考文献21

  • 1中华人民共和国卫生部.医院感染管理办法[S].北京,2006.
  • 2Peleg AY, Seifert H, Palerson DL. Acinetobacter baumannii : emerpence of a successful pathogen[J]. Clin Micpobiol Rev, 2008,21 (3) : 538-582.
  • 3Weber DJ,Anderson D,Rutala WA.The role of the surface environment in healthcare-associated infections[J].Curr Opin Infect Dis,2013,26(4):338-344.
  • 4Weber DJ,Rutala WA.Understanding and preventing transmission of healthcare-associated pathogens due to the contaminated hospital environment[J].Infect Control Hosp Epidemiol,2013,34(5):449-452.
  • 5Donskey CJ.Does improving surface cleaning and disinfection reduce health care-associated infections[J].Am J Infect Control,2013,41(5Suppl):S12-19.
  • 6Huslage K,Rutala WA,Sickbert-Bennett E,et al.A quantitative approach to defining high-touch surfaces in hospitals[J].Infect Control Hosp Epidemiol,2010,31(8):850-853.
  • 7Datta R,Platt R,Yokoe DS,et al.Environmental cleaning intervention and risk of acquiring multidrug-resistant organisms from prior room occupants[J].Arch Intern Med,2011,171(6):491-494.
  • 8Rutala WA,Gergen MF,Weber DJ.Microbiologic evaluation of microfiber mops for surface disinfection[J].Am J Infect Control,2007,35(9):569-573.
  • 9Xu H,Jin H,Zhao L,et al.A randomized,double-blind comparison of the effectiveness of environmental cleaning between infection control professionals and environmental service workers[J].Am J Infect Control,2015,43(3):292-294.
  • 10Ragan K,Khan A,Zeynalova N,et al.Use of audit and feedback with fluorescent targeting to achieve rapid improvements in room cleaning in the intensive care unit and ward settings[J].Am J Infect Control,2012,40(3):284-286.

共引文献34

同被引文献165

引证文献21

二级引证文献89

相关作者