期刊文献+

基于天空模型的公共场所照明智能控制 被引量:3

Intelligent Control Strategy of Illumination in Locus Public Based on Sky Model
在线阅读 下载PDF
导出
摘要 公共场所照明具有全天候、多应用、能耗大的特点;掌握任意时间的天空亮度分布情况是充分利用自然光、实现智能照明的基础;基于国际照明委员会(CIE)给出的天空亮度计算公式,建立自然光对公共照明区域产生的天空照度模型;引入数学和光学相关原理建立公共场所人造光和自然光的混合模型;利用改进蚁群算法求解模型,得出最佳的灯具亮度组合,实现舒适和及节能的综合最优;最后,选择典型的大跨度带天窗建筑物为采光对象完成仿真实验,实验结果验证该策略的有效性。 Locus lighting has the characteristics of all-weather operation,variable demand and large energy consumption.Knowing the distribution of sky luminance at any time is the foundation to make full use of natural light and realize intelligent lighting.Sky illumination model was established based upon formula for calculating sky brightness from the International Commission on Illumination (CIE).A hybrid model of combining artificial light with natural light was established using optical principles.The best combination of lighting fixtures luminance is solved out by use of the improved ant colony algorithm,hence realizing the comprehensive optimum of comfort and energy-saving.Finally,the effectiveness of control strategy was verified by simulation of large span building.
出处 《计算机测量与控制》 2017年第8期50-53,67,共5页 Computer Measurement &Control
基金 国家自然科学基金资助项目(51375290 71001060) 上海航天科技创新基金(SAST2015054) 中央高校基本科研业务费学科交叉-面上项目(1000219176)
关键词 智能照明 天空模型 蚁群算法 节能 intelligent lighting sky model ant colony algorithm energy-saving
  • 相关文献

参考文献6

二级参考文献83

  • 1陈勇旗,谭冠政.无线遥控智能照明系统[J].电气应用,2005,24(2):53-56. 被引量:7
  • 2陈仲林.有缝导光管的管道[J].灯与照明,1995,18(2):28-33. 被引量:1
  • 3周长吉,丁小明,杜孝明.温室用聚碳酸酯中空板辐射透过特性初步研究[J].农业工程学报,2006,22(11):192-196. 被引量:8
  • 4Lornea Whiteheed, Krist in Hoffman. Method for estimating the efficiency of prism light guide lumnaires. Journal of IES, summer 1988.
  • 5Muhs, Jeff. Hybrid solar lighting doubles the efficiency and affordability of solar energy in commercial buildings. CADDET Energy Efficiency. 2002b.
  • 6Jenkins D, Muneer T. Modelling light -pipe performances - a natural daylighting solution. Building Environment, 2003.38 (9) : 65-72.
  • 7Zhang X, Muneer T. A design guide for performance assessment of solar light - pipe. Lighting Research and Technology, 2002. 34 (2): 149-69.
  • 8Laouadi A, Atif MR. Prediction model of optical characteristics for domed skylights under standard and real sky- conditions. In: 7th International IBPSA conference (Rio de Janeiro, Brazil, Aug, 2001), 2001:1101 1108.
  • 9Carter DJ. The measured and predicted performances of passive solar light - pipe systems. Lighting Research and Technology, 2002.34 (1): 39 - 52.
  • 10Chartered Institution of Building Services Engineers. The calculation and use of utilization factors, Technical Memoranda 5. London: Chartered Institute of Building Engineers. 1980.