期刊文献+

A sensitive and compact mercury analyzer by integrating dielectric barrier discharge induced cold vapor generation and optical emission spectrometry 被引量:1

A sensitive and compact mercury analyzer by integrating dielectric barrier discharge induced cold vapor generation and optical emission spectrometry
原文传递
导出
摘要 An environmentally friendly,low power consuming,sensitive and compact mercury analyzer was developed for the determination of mercury in water samples by integrating a thin film dielectric barrier discharge induced cold vapor reactor and a dielectric barrier discharge optical emission spectrometer into a small polymethyl methacrylate plate(10.5 cm length×8.0 cm width×1.2 cm height).Mercury cold vapor was generated when standard or sample solutions with or without formic acid were introduced to the reactor to form thin film liquid and exposed to microplasma irradiation and subsequently separated from the liquid phase for transport to the microplasma and detection of its atomic emission.Limits of detection of 0.20 μg L^-1 and 2.6 μg L^-1 were obtained for the proposed system using or not using formic acid,respectively.Compared to the conventional microplasma optical emission spectrometry used for mercury analysis,this system not only retains the good limit of detection amenable to the determination of mercury in real samples,but also reduces power consumption,eliminates the generation of hydrogen and avoids the use of toxic or unstable reductant.Method validation was demonstrated by analysis of a certified reference material of water sample and three real water samples with good spike recoveries(88-102%). An environmentally friendly,low power consuming,sensitive and compact mercury analyzer was developed for the determination of mercury in water samples by integrating a thin film dielectric barrier discharge induced cold vapor reactor and a dielectric barrier discharge optical emission spectrometer into a small polymethyl methacrylate plate(10.5 cm length×8.0 cm width×1.2 cm height).Mercury cold vapor was generated when standard or sample solutions with or without formic acid were introduced to the reactor to form thin film liquid and exposed to microplasma irradiation and subsequently separated from the liquid phase for transport to the microplasma and detection of its atomic emission.Limits of detection of 0.20 μg L^-1 and 2.6 μg L^-1 were obtained for the proposed system using or not using formic acid,respectively.Compared to the conventional microplasma optical emission spectrometry used for mercury analysis,this system not only retains the good limit of detection amenable to the determination of mercury in real samples,but also reduces power consumption,eliminates the generation of hydrogen and avoids the use of toxic or unstable reductant.Method validation was demonstrated by analysis of a certified reference material of water sample and three real water samples with good spike recoveries(88-102%).
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2017年第2期189-196,共8页 中国化学快报(英文版)
基金 the National Natural Science Foundation of China(No.21575092)for financial support
关键词 Mercury Real time field analysis Microplasma Optical emission spectrometry Cold vapor generation Miniaturization Mercury Real time field analysis Microplasma Optical emission spectrometry Cold vapor generation Miniaturization
  • 相关文献

参考文献1

二级参考文献3

共引文献4

同被引文献17

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部