摘要 Background: Currently, transcatheter closure of perimembranous ventricular septal defect (pmVSD) is a widely accepted therapeutic modality. However, arrhythmias, especially postprocedural heart blocks, are a concern and outcomes are not very clear. This study explored the outcomes and risk factors of arrhythmias associated with transcatheter device closure ofpmVSD. Methods: A total of 395 patients diagnosed with pmVSD who successfully underwent transcatheter intervention between January 2010 and December 2015 in our center were retrospectively reviewed. Electrocardiographic data before and after the procedure were collected and analyzed. We first evaluated the potential risk factors including gender, age, weight, inlet and outlet diameters of defect, subaortic rim length, occluder size, corrected occluder size into body surface area, fluoroscopy time, presence of aneurysm, and deployment position. We compared the potential risk factors between arrhythmia and nonarrhythmia groups using univariate analysis, followed by logistic analysis for independent risk factors. Results: Various arrhythmias were detected in 95 cases (24.1%) following transcatheter closure procedure. Logistic regression analysis revealed that eccentric (odds ratio [OR] 2.9, 95% confidence interval [(CI]: 1.2-7.2) and large occluders (OR 2.0, 95% (.7: 1.6-2.5), as well as long fluoroscopy time (OR 1.1, 95% CI: 1.1-1.2), were correlated with postprocedural arrhythmia. During 35.5 months (range: 9-80 months) of follow-up, most of the patients (74 out of 95) reverted to normal heart rhythm. Conclusions: The mid-term outcome of patients with arrhythmias after transcatheter closure of pmVSD was satisfactory as most of the patients recovered normal rhythm. Eccentric, large device and long fluoroscopy time increase the risk of arrhythmias after transcatheter closure of pmVSD. Background: Currently, transcatheter closure of perimembranous ventricular septal defect (pmVSD) is a widely accepted therapeutic modality. However, arrhythmias, especially postprocedural heart blocks, are a concern and outcomes are not very clear. This study explored the outcomes and risk factors of arrhythmias associated with transcatheter device closure ofpmVSD. Methods: A total of 395 patients diagnosed with pmVSD who successfully underwent transcatheter intervention between January 2010 and December 2015 in our center were retrospectively reviewed. Electrocardiographic data before and after the procedure were collected and analyzed. We first evaluated the potential risk factors including gender, age, weight, inlet and outlet diameters of defect, subaortic rim length, occluder size, corrected occluder size into body surface area, fluoroscopy time, presence of aneurysm, and deployment position. We compared the potential risk factors between arrhythmia and nonarrhythmia groups using univariate analysis, followed by logistic analysis for independent risk factors. Results: Various arrhythmias were detected in 95 cases (24.1%) following transcatheter closure procedure. Logistic regression analysis revealed that eccentric (odds ratio [OR] 2.9, 95% confidence interval [(CI]: 1.2-7.2) and large occluders (OR 2.0, 95% (.7: 1.6-2.5), as well as long fluoroscopy time (OR 1.1, 95% CI: 1.1-1.2), were correlated with postprocedural arrhythmia. During 35.5 months (range: 9-80 months) of follow-up, most of the patients (74 out of 95) reverted to normal heart rhythm. Conclusions: The mid-term outcome of patients with arrhythmias after transcatheter closure of pmVSD was satisfactory as most of the patients recovered normal rhythm. Eccentric, large device and long fluoroscopy time increase the risk of arrhythmias after transcatheter closure of pmVSD.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2017年第5期516-521,共6页 中华医学杂志(英文版)
关键词 Arrhvthmia OCCLUDER OUTCOMES Percutaneous Closure Perimembranous Ventricular Septal Defect Risk Factors Arrhvthmia Occluder Outcomes Percutaneous Closure Perimembranous Ventricular Septal Defect Risk Factors
  • 相关文献

参考文献6

二级参考文献42

共引文献71

同被引文献57

引证文献8

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部