摘要
目的:建立柴胡注射液细菌内毒素检查法。方法:依据《中国药典》2010年版附录中细菌内毒素检查法,通过预干扰和干扰试验确定样品最大无干扰浓度,并进行方法学验证。结果:将柴胡注射液稀释200倍,对细菌内毒素检查法无干扰作用。结论:建立的方法用于检查柴胡注射液的细菌内毒素可行。
Objective: To establish a method for bacterial endotoxin test of Chaihu injection. Method: Maximal non-interference concentrations of samples were determined by pre-interference test according to the appendix of Chinese Pharmacopiea(2010 edition). And then methodology validation was conducted. Results: The interference on bacterial endotoxin test could be excluded when the sample was diluted 200 times. Conclusion:The established method is feasible to detect the bacterial endotoxin of Chaihu injection.
出处
《中国药事》
CAS
2017年第2期174-177,共4页
Chinese Pharmaceutical Affairs
关键词
柴胡注射液
细菌内毒素检查
凝胶法
干扰试验
Chaihu injection
Bacterial endotoxin test
Gel-clot
Interference test