摘要
C2 0混凝土试块在 4 5 0℃高温下持续不同时间后自然冷却 ,再对其进行超声、回弹综合法及标准抗压强度试验 ,以探讨同一高温不同时间作用后混凝土强度的变化规律 。
Comprehensive method of ultrasonic testing and standard compressive strength test was used to deal with C20 concrete heated under high temperature of 450℃ with different time. The regularity of concrete strength with the same temperature and different time was studied and the relationship between nondestructive testing and standard compressive strength test was analyzed.
出处
《无损检测》
2002年第8期339-340,361,共3页
Nondestructive Testing
关键词
无损检测
超声检验
高温
混凝土
强度
Ultrasonic testing
High temperature
Concrete
Strength