Asir-V联合“双低”扫描技术在儿童先天性心脏病诊断中的应用 被引量:5

Application value of Asir-V plus "double low" scan technique in children with congenital heart disease
暂未订购
导出
摘要 目的:阐述 Revolution CT 低剂量扫描技术在儿童先天性心脏病(congenital heart diseas, CHD)中的应用价值。方法选择 CHD 患儿34例,随机分为两组,A 组17例,Asir— V:50%,B 组:17例,Asir—V:80%,两组扫描条件均为70 Kv,300 mAs,探测器宽度120~160 mm,扫描时间0.3 s,造影剂:碘海醇350 mgI /mL,用量1 mL/kg,记录升主动脉、降主动脉、肺动脉主干、左心室的 CT 值及同层面背部软组织 CT 值,根据标准差 SD 计算各兴趣区信噪比(signal-to-noise ratio,SNR)及对比信噪比(contrast-to-noise ratio,CNR),记录每个病例的剂量长度乘积(dose-length product,DLP),并根据公式换算有效剂量(effective doses,ED),由两位工作10年以上的副主任医师独立读片诊断并对图像质量进行评分。结果A 组各兴趣区 SNR 及 CNR 小于 B 组,差异有统计学意义(P >0.01),A 组 DLP 及 ED 与 B 组比较,差异无统计学意义(P <0.01),两位医师读片显示病例图像质量良好,读片结果一致性良好(K =0.621、0.683);结论CTA 是小儿先天性心脏病的重要诊断手段,“双低”技术保证图像质量的前提下有效减少了 CT 辐射剂量,Asir—V:80%会获得更高的图像信噪比。 Objetive To explore the value of Asir-V plus low-dose scanning technique in children with congenital heart disease (CHD).Methods Thirty-four CHD children were randomly divided into group A (n=1 7),Asir-V:50% and group B (n =1 7),Asir-V:80%.The scanning conditions of two groups were 70 Kv,300 mAs,detector width 1 20 ~1 60 mm,scanning time 0.3 s,contrast agent:350 mgI /mL and dosage 1 mL/kg.The values of computed tomography (CT)were recorded for ascending aorta,descending aorta,pul-monary artery and left ventricle.Standard deviation (SD)was calculated for area of interest signal -to -noise ratio (SNR)and contrast ratio of signal-to-noise ratio (CNR).Dose length product (product dose-length, DLP)was recorded for each case and effective dose (ED)was converted according to the formula.Medical di-agnosis was made and image quality scored independently by two experienced doctors. Results The values of CNR and SNR of group A were less than those of group B.The differences were statistically significant (P 〈0.01 ).The inter -group differences of DLP and ED were statistically insignificant (P 〉0.05).Two inde-pendent doctors reviewed the films to ensure the image quality of each case and the consistency was decent (K=0.621 ,0.683). Conclusions Computed tomography angiography is an important diagnostic means for children with congenital heart disease.And “double low”technology is applied for ensuring image quality under the premise of effectively reducing CT radiation dose and improving Asir-V with a higher image SNR ratio.
出处 《临床小儿外科杂志》 CAS 2016年第5期494-496,517,共4页 Journal of Clinical Pediatric Surgery
关键词 心脏病/先天性 迭代算法 双低 儿童 Heart Diseases/CN Asir-V Double low Child
  • 相关文献

参考文献7

  • 1Krishnamurthy R. The role of MRI and CT in congenital heart disease[ J]. Pediatr Radiol,2009,39 (Suppl 2) :S196 - $204.
  • 2杨有优,王思云,周旭辉,李向民,彭谦,李子平,孟悛非.64层螺旋CT诊断复杂先天性心脏病及与超声心动图和手术对照[J].临床放射学杂志,2007,26(10):1029-1032. 被引量:34
  • 3王慧慧,王鹤,王霄英,姜健,高福生,张保翠.100kVp条件下碘克沙醇(270mgI/mL)应用于分次团注双期CTU的可行性研究[J].放射学实践,2014,29(4):373-377. 被引量:14
  • 4Huang MP, Liang CH, Zhao ZJ, et al, Evaluation of image quality and radiation dose at prospective ECG-triggered axial 256-slice multi-detector CT in infants with congenital heartdisease [ J ]. Pediatr Radio1,2011,4I ( 7 ) : 858 - 866.
  • 5Hara AK, Paden RG, Silva AC, et al. 1 terative reeonstruction technique for reducing body radiation dose at CT:feasibility study [ J ]. A JR Am J Roentgenol, 2009,193 ( 3 ) : 764-771.
  • 6Wintersperger B, Jakobs T, Herzog P, et al. Aortoiliac mul- tidetector-row CT angiography with low kV settings: im- proved vessel enhancement and simtdtaneous reduction of radiation dose [ J ]. Eur Radiol, 2005,15 ( 2 ) :334 -341.
  • 7Cheng A, Wang X, Duan Y, et al. Low-dose prospective ECG- triggering dual-source CT angiography in infants and chil- dren with complex congenital heart disease:first experience [ J ]. Eur Radiol,2010,74 (3) :487 -492.

二级参考文献34

  • 1Nikolaou K, Flohr T, Knez A,et al. Advances in cardiac imaging: 64 slice scanner. Int J Cardiovasc Imaging, 2004, 20:535
  • 2Gilkeson RC, Ciancibello L, Zahka K. Muhidetector CT evaluation of congenital heart disease in pediatric and adult patients. AJR, 2003, 180:973
  • 3Coo HW, Park IS, Ko JK,et al. Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients. Int J Cardiovasc Imaging, 2005, 21:347
  • 4Bean M J, Pannu H, Fishman EK. Three-Dimensional computed tomographic imaging of complex congenital cardiovascular abnormalities. J Comput Assist Tomogr, 2005, 29:721
  • 5Hemminger BM, Molina PL, Egan TM,et al. Assessment of realtime 3D visualization for cardiothoracic diagnostic evaluation and surgery planning. Journal of Digital Imaging, 2005, 18 : 145
  • 6Van Praagh R. The segmental approach clarified. Cardiovase Intervent Radiol, 1984, 7:320
  • 7Coo HW, Park IS, Ko JK, et al. CT of congenital heart disease: Normal anatomy and typical pathologic conditions. Radiographics, 2003, 23 : 147
  • 8Sklansky M. Advances in Fetal Cardiac Imaging. Pediatr Cardiol, 2004, 25:307
  • 9Funabashi N, Rubin GD. Qualitative blood flow differentiation-depiction of a left to fight eanliac shunt across a ventricular sepial defect using Electron-beam computed tomography. Japan Circ J, 2000, 64:901
  • 10Boechat MI, Ratib O, Williams PL,et al. Cardiac MR imaging and MR angiography for assessment of complex tetralogy of Fallot and pulmonary atresia. Radiographics, 2005, 25:1535

共引文献46

同被引文献23

引证文献5

二级引证文献90

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部