摘要 提出了一种新的空气源热泵热水器,该空气源热泵热水器具有两个室外换热器,能够实现从室外空气中吸热化霜,化霜时还能继续供热,克服了现有除霜技术的缺陷;本文介绍了该空气源热泵热水器的工作流程及控制方法。 This article presents a kind of new air source heat pump water heater which has two outdoor heat exchangers. The exchangers can defrost through absorbing heat from outdoor air and keep supplying heat at the same time which overcomes the drawback of current defrosting technology. This paper introduces the working process and control methods of the air source heat pump water heater.
出处 《建筑热能通风空调》 2016年第10期88-90,55,共4页 Building Energy & Environment
关键词 空气源 热泵 热水器 除霜 air source heat pump water heater defrosting
  • 相关文献

参考文献10

  • 1Baxter D,Moyers JC.Field-measured cycling,frost and defrostin -g losses for a high efficiency air source heat pump[J].ASHRAE Trans,1985,91(2B-2):537-554.
  • 2姚扬,姜益强,马最良,等.蓄能式空气源热杲除霜系统(中国200510009975.1)[P].2005-05-12.
  • 3韩志涛,姚杨,马最良,姜益强.空气源热泵蓄能热气除霜新系统与实验研究[J].哈尔滨工业大学学报,2007,39(6):901-903. 被引量:32
  • 4韩志涛.空气源热泵常规除霜与蓄能除霜特性实验研究[D].哈尔滨:哈尔滨工业大学学报,2008.
  • 5姜益强,姚扬,胡文举,等.非间断供热相变蓄能除霜系统(中国200810136918.3)[P].2008-08-13.
  • 6孟琪林,段亮,陈绍林,等.热泵式空调系统及其除霜方法(中国201210269782.X)[P].2012-07-30.
  • 7Zhang Long,Dong Jiankai,Jiang Yiqiang,et al.A novel defrostin -g method using heat energy dissipated by the compressor of an air source heat pump[J].Aplied Energy,2014,133:101-111.
  • 8刘雄.空调制冷设备:201110028741.7[P].2011-07-06.
  • 9刘雄.制冷剂三通流向转换装置(中国201110355023,0)[P].2011-10-31.
  • 10刘雄.制冷剂三通流向转换装置(中国201220164553.7)[P].2012-04-10.

二级参考文献5

  • 1王少为,刘震炎,赵可可,王志刚.蓄能和热水器复合空调器冬季运行试验研究[J].流体机械,2004,32(9):45-48. 被引量:7
  • 2张建忠 龚延风.空气源热泵冷热水机组在南京的应用[J].现代空调,2001,(3):141-156.
  • 3BAXTER V D,MOYERS J C.Field-measured cycling,frosting and defrosting losses for a hiish efficiency air source heat pump[J].ASHRAE Trans,1985,91(2B-2):537-554.
  • 4MATSUSHITA DENKI SANGYO KK(MATU).Heat pump type air conditioning and hot water supply equipmerit,uses heat exchange device to exchange heat between hot water of storage tank and refrigerant in outdoor heat exchanger.Japan:JP200218944-A[P].
  • 5刘志强,汤广发,赵福云.风冷热泵除霜过程动态特性模拟和实验研究[J].制冷学报,2003,24(3):1-5. 被引量:10

共引文献32

同被引文献13

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部