期刊文献+

降低电厂氢型混床能耗的措施 被引量:2

Measures for Reducing Energy Consumption of Hydrogen-type Mixed Bed in Power Plant
在线阅读 下载PDF
导出
摘要 以湛江中粤能源有限公司为例,针对氢型混床能耗过高的问题,研究其影响因素并提出相应的解决措施,重点包括降低给水pH值的控制上限、优化混床阳阴树脂配比、提高树脂分离过程的监控精度和调整工艺步序等。这些措施实施后,氢型混床周期制水量增大近300%,混床每处理1 m^3凝结水所消耗的除盐水量、酸碱量降低约70%。 In allusion to the problem of high energy consumption of hydrogen-type mixed bed, this paper takes Zhanjiang Zhongyue energy co. ltd. for an example, studies influencing factors on energy consumption and presents related solutions such as reducing upper control limit of pH value for feedwater, optimization on cation-anion resin proportioning, improving monitoring precision for resin separation, adjusting process steps, and so on. After implementing these measures, period water volume of the hydrogen-type mixed bed increases about 300%, and when the mixed bed processes 1 m3 condensate water per time, amount of demineralized water and acid-base amount both decreases about 70%.
出处 《广东电力》 2016年第9期32-36,共5页 Guangdong Electric Power
关键词 凝结水精处理 氢型混床 树脂分离 树脂配比 工艺步序 节能降耗 condensate water precision processing hydrogen-type mixed bed resin separation resin proportioning process step energy conservation and consumption reduction
  • 相关文献

参考文献10

  • 1田文华.我国火电厂凝结水精处理存在的问题和对策[C]//电厂化学2013年学术年会论文集.长沙:中国电机工程学会火力发电分会,2013.
  • 2GB/T12145-2008,火力发电机组及蒸汽动力设备水汽质量[S].2008.
  • 3田文华,李鹏,和慧勇.空冷机组凝结水精处理系统设备优化配置[J].热力发电,2009,38(3):81-84. 被引量:12
  • 4朱志平,黄可龙,周艺,周琼花.汽轮机初凝区腐蚀机理分析[J].腐蚀科学与防护技术,2006,18(1):20-23. 被引量:28
  • 5DL/T 1201-2013,发电厂低电导率pH的在线测量方法[S].
  • 6DL/T 5068-2014,发电厂化学设计规范[S].
  • 7李锐,朱洪.热力发电厂凝结水精处理现状与探讨[C]//电厂化学2008年学术年会论文集.长沙:中国电机工程学会火力发电分会,2008.
  • 8田文华,雷俊茹,祝晓亮,钱殷,叶洲,刘屹然.高速混床树脂分离与输送过程的智能监控[J].中国电力,2015,48(11):22-25. 被引量:19
  • 9DL/T333.1-2010火电厂凝结水精处理系统技术要求第1部分:湿冷机组[S].
  • 10祝晓亮,田文华,李荣荣,等. 一种加强型两级高速混床进水分配装置:中国,201420622942.6[P]:2015-02-04.

二级参考文献14

  • 1朱兴宝,熊京川,梁桥洪.岭澳核电站二期凝结水处理系统重大技术改进[J].核动力工程,2009,30(S2):1-5. 被引量:13
  • 2朱志平,杨道武,李立平.氨对炉水pH值的影响程度分析[J].中国电力,2003,36(11):57-60. 被引量:7
  • 3孙永.汽轮机低压缸铸钢部件酸腐蚀的原因分析[J].热力发电,1985,2:24-24.
  • 4李志刚 孙永.离子交换树脂在高温高压下的分解[J].热力发电,1986,5:50-50.
  • 5田文华 和慧勇.直接空冷机组凝结水精处理系统存在的问题及对策.热力发电,2008,37(4):94-97.
  • 6ASTM D4519- 94(2005),Standard Test Method for On- Line Determination of Anions and Carbon Dioxide in High Purity Water by Cation Exchange and Degassed Cation Conductivity[S].
  • 7Hitzel H,Conlin J B. Further results of condensate polishing with separate cation and anion exchangers in the direct air cooled power station Marimba of ESKOM[J]. VGB Kraftwerkstechnik, 1991,71(1):58 - 61.
  • 8龚询洁.热力设备的腐蚀与防护[M].北京:中国电力出版社,1998,5..
  • 9韩隶传,李志刚.凝结水精处理混床机理和应用研究[J].中国电力,2007,40(12):90-93. 被引量:30
  • 10DL/T 333.1-2010 火电厂凝结水精处理系统技术要求 第1部分:湿冷机组[S].

共引文献67

同被引文献25

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部