针对串联型交流电压调节器 ,提出了一种新的基波正序计算方法以获取补偿电压的参考信号。这种方法不需要硬件同步电路 ,能实时地计算电源电压中的基波正序分量。在以DSP为平台的样机上进行了交流调压的实验。实验结果表明 ,基于新的电源电压基波正序计算方法的串联型电压调节器能有效地补偿电源电压的跌落、畸变及不平衡 ,适应各种负载 。
A series ac voltage regulator based on a new fundamental positive sequence calculation method, which is utilized to generate the compensation voltage reference, is introduced in this paper. The proposed method doesn't need hardware synchronization circuit and can perform the calculation of fundamental positive sequence component of the supply voltage in real time. Experiments based on DSPs were performed on the prototype,and the results indicate that the regulator based on the proposed approach works well under such conditions as source voltage sag, distortion and unbalance. Moreover, it is suitable for many kinds of load and has a good dynamic performance.