摘要
某区域供热锅炉房三面紧邻居住小区,噪声问题严重。在对锅炉房进行噪声测量与声源分析的基础上,提出噪声治理措施,包括设备基础改造、厂房内设置吸声墙壁与吊顶、增设设备隔声罩与隔声屏、加装烟道消声器、改造门窗、改造管道支架等。实施后效果良好。
A district heating boiler room is closely embraced on three sides by residential areas, which leads to serious noise problems. On the basis of monitoring and analyzing noise sources of the heating boiler room, some specific measures to control the noise are put forward, including remaking the basement of equipment, setting up sound-absorbing walls and ceilings within the plant, adding acoustic enclosures and acoustic screens of equipment, installing silencers in flue pipes, transforming doors, windows and piping supports and so on. The implementation effect is good.
出处
《煤气与热力》
2016年第7期1-3,共3页
Gas & Heat
关键词
区域供热锅炉房
噪声
隔声
吸声
district heating boiler room noise sound isolation sound adsorption