期刊文献+

大直径股骨头金属对金属全髋关节置换术的中期随访结果 被引量:9

Mid-term effects of total hip arthroplasty using metal-on-metal prosthesis with large diameter femoral head
原文传递
导出
摘要 目的 探讨大直径股骨头金属对金属全髋关节置换术的中期临床疗效。方法对2007年3月至2009年12月采用大直径金属对金属全髋关节置换术治疗的153例(177髋)晚期髋关节疾病患者进行回顾性分析。通过临床体格检查和影像学表现评价髋关节功能及并发症(假体松动及炎性假瘤形成)的发生率;采用ICP-MS方法测定患者血清中金属钻离子和铬离子浓度,并与正常人群参考值进行比较;以翻修为假体生存终点事件,计算假体五年生存率。结果145例(169髋)获得随访,随访率为94.8%(145/153);随访时间67-80个月,平均72.4个月。其中男85例(104髋),女60例(65髋);年龄20±78岁,平均(49.3±12.6)岁。所有患者均采用ASRTM-XL大直径股骨头金属对金属全髋关节假体。末次随访时Harris髋关节评分由术前(44.2±12.6)分提高至(91.5±5.7)分;3例(2.1%,3/145)出现臼杯完全松动、5例(3.4%,5/145)出现髋部炎性假瘤而接受翻修手术。以翻修为终点,术后五年假体生存率为95.3%(161/169)。患者血清钴离子和铬离子浓度分别为2.89μg/L和3.31μg/L,明显高于正常人群参考值(〈0.5μg/L)。结论大直径股骨头金属对金属全髋关节置换术后随访中期可出现臼杯松动和炎性假瘤形成,假体生存率较低。患者血清钴离子和铬离子浓度明显升高。对初次全髋关节置换术,大直径股骨头金属对金属假体不宜作为首选。 Objective To evaluate mid-term clinical outcomes associated with total hip arthroplasty using metal-on-metal prosthesis with large diameter femoral head. Methods From March 2007 to December 2009, 153 patients (177 hips) with advanced hip diseases undergoing large diameter femoral head metal-on-metal total hip arthroplasty in our hospital were retrospectively analyzed in this study. Clinical physical examination and radiographic examination were used to evaluate hip function and the incidence of complications (implant loosening and inflammatory pseudotumor); ICP-MS method was used to determine serum cobalt ion and chromium ion levels and compare with normal values; revision was set as the prosthesis endpoint to evaluate the five year survival rate of implant. Results A total of 145 patients (159 hips) were followed up for average 72.4 months (67-80 months), the follow-up rate was 94.8% (145/153). For the involved patients, 85 were male (104 hips), 60 were female (65 hips); age 20-78 years old, average 49.3±12.6 years old. All patients received ASR^TM-XL large femoral head metal-on-metal total hip arthroplasty operation. At the end of follow-up, the average Harris hip score improved from 44.2± 12.6 points preoperatively to 91.5±5.7 points. A total of 8 patients received revision, 3 for acetabular implant spinout-out and 5 for hip inflammatory pseudotumor. The prosthetic survival rate 5 years after operation was 95.3% (151/159) for revision. Serum cobalt (2.89 μg/ L) and chromium (3.31μg/L) ion levels were significantly increased compared with normal value (〈 0.5 μg/L). Conclusion For the fixation and friction interface disadvantages, acetabular implant spinout-out and inflammatory pseudotumor might occur for patient receiving large femoral head metal-on-metal THA. The mid-term prosthetic survival rate was also low, with metal ion levels increased significantly. For primary THA, large femoral head metal-on-metal prosthesis cannot be the first choice.
出处 《中华骨科杂志》 CAS CSCD 北大核心 2016年第7期385-391,共7页 Chinese Journal of Orthopaedics
基金 国家卫生计生委卫生行业科研专项基金(201302007)
关键词 关节成形术 置换 假体和植入物 肉芽肿 浆细胞 铬合金 Arthroplasty, replacement, hip Prostheses and implants Granuloma, plasma cell Chromium alloys
  • 相关文献

参考文献21

  • 1Berry. D J, yon Knoch M, Schleck CD. Effect of femoral head diam- eter and operative approaeh on risk of dislocation 'after primary to- tal hip arthroplasty[J]. J Bone Joint Surg Am, 2005, 87(11): 2456- 2463.
  • 2Smith TM, Berend KR, Lombardi Jr AV. Metal-on-metal total hip arthroplasty with large heads may prevent early dislocation[J]. Clin Orthop Relat Res, 2005(441): 137-142.
  • 3Cuckler JM, Moore KD, Lombardi Jr AV. Large versus small femo- ral heads in metal-on-metal total hip arthroplasty[J]. J Arthroplas- ty, 2004, 19(8 Suppl 3): S41-44.
  • 4Bosker BH, Ettema HB, van Rossum M. Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips [J]. Arch Othop Trauma Surg, 2015, 135(3): 417-425.
  • 5Hailer NP, Bengtsson M, Lundberg C. High metal ion levels after use of the ASRTM device correlate with development of pseudotu- mors and T cell activation[J]. Clin Orthop Relat Res, 2014, 472 (3): 953-961.
  • 6Reito A, Puolakka T, Elo P. High prevalence of adverse reactions to metal debris in small-headed ASR^TM hips[J]. Clin Orthop Relat Res, 2013, 471(9): 2954 - 2961.
  • 7Steele GD, Fehring TK, Odum SM. Early failure of articular sur- face replacement XL total hip arthroplasty[J]. J Arthroplasty, 2011, 26(6 Suppl): S14-18.
  • 8Bolland BJ, Culliford DJ, Langton DJ. High failure rates with a large-diameter hybrid metal-on-metal total hip replacement: clini- cal, radiological and retrieval analysis[J]. J Bone Joint Surg Br, 2011, 93(5): 608-615.
  • 9Naal FD, Pilz R, Munzinger U. High revision rate at 5 years after hip resuffacing with the Durom implant[J]. Clin Orthop Relat Res, 2011,469(9): 2598-2604.
  • 10Munro JT, Masri BA, Duncan CP. High complication rate 'after re- vision of large-head metal-on-metal total hip arthroplasty[J]. Clin Orthop Relat Res, 2014, 472(2): 523-528.

二级参考文献107

  • 1Amstutz HC,Lodwig RM,Schurman DJ,et al.Range of motion studies for total hip replacements.A comparative study with a new experimental apparatus.Clin Orthop Relat Res,1975(111):124-130.
  • 2Matsushita A,Nakashima Y,Jingushi S,et al.Effects of the femoral offset and the head size on the safe range of motion in total hip arthroplasty.J Arthroplasty,2009,24(4):646-651.
  • 3Burroughs BR,Hallstrom B,Golladay GJ,et al.Range of motion and stability in total hip arthroplasty with 28-,32-,38-,and 44-mm femoral head sizes.J Arthroplasty,2005,20(1):11-19.
  • 4Langton DJ,Jameson SS,Joyce TJ,et al.Early failure of metalon-metal bearings in hip resurfacing and large-diameter total hip replacement:A consequence of excess wear.J Bone Joint Surg (Br),2010,92(1):38-46.
  • 5Ollivere B,Darran C,Barker T,et al.Early clinical failure of the Birmingham metal-on-metal hip resurfacing is associated with metaliosis and soft-tissue necrosis.J Bone Joint Surg (Br),2009,91(8):1025-1030.
  • 6Browne JA,Bechtold CD,Berry DJ,et al.Failed metal-on-metal hip arthroplnsties:a spectrum of clinical presentations and operative findings.Clin Orthop Relat Res,2010,468(9):2313-2320.
  • 7Pradhan R.Planar anteversion of the acetabular cup as determined from plain anteroposterior radiographs.J Bone Joint Surg (Br),1999,81(3):431-435.
  • 8DeLee JG,Gharnley J.Radiological demarcation of cemented sockets in total hip replacement.Glin Orthop Relat Res,1976(121):20-32.
  • 9Kim YH,Kim VE.Uncemented porous-coated anatomic total hip replacement.Results at six years in a consecutive series.J Bone Joint Surg (Br),1993,75(1):6-13.
  • 10Teloken MA,Bissett G,Hozack WJ,et al.Ten to fifteen-year follow-up after total hip arthroplasty with a tapered cobalt-chromium femoral component (tri-lock) inserted without cement.J Bone Joint Surg (Am),2002,84(12):2140-2144.

共引文献15

同被引文献65

引证文献9

二级引证文献2505

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部