空间高可靠高压变压器局部放电分析与检测 被引量:1

Partial discharge analysis and test of high-voltage transformer in high power supply of STWTA
在线阅读 下载PDF
导出
摘要 基于空间用行波管电源高压变压器的绕组结构及灌封缺陷,分析了行波管电源高压变压器的局部放电机理,提出了用脉冲电流法检测高压变压器的局部放电。介绍了局部放电检测中的脉冲电流法机理,检测系统的构成以及变压器局部放电的检测方法及抗干扰措施。通过局部放电检测,成功地剔除了有灌封缺陷的高压变压器,保证了空间行波管放大器的长寿命运行,避免了行波管高压电源在低气压下放电的发生。最后介绍了一款国外专用于高压电子元器件局部放电的检测系统。 Based on the composition and the poting defection of High-voltage transformer used in space traveling wave tube amplifier(STWTA), partial discharge(PD) mechanism of High-voltage transformer was analyzed. The partial discharge detection with pulse current method was carried out. The principle of pulse current method of The partial discharge(PD and the constitution of the partial discharge test apparatus was introduced. The test method and the measure of anti-interference of the partial discharge detection in transformer were introduced. This PD test in High-voltage transformer rejected the transformer with potting defection, and the low air discharge of EPC was avoided, making sure that the reliability and long life of the STWTA.
作者 孙小平 王刚
出处 《电源技术》 CAS CSCD 北大核心 2016年第3期642-644,718,共4页 Chinese Journal of Power Sources
关键词 空间行波管放大器电源 高压变压器 局部放电分析及检测 high power supply of STWTA high-voltage transformer partial discharge analysis and test
  • 相关文献

参考文献1

二级参考文献6

  • 1王纯敬.局部放电试验中的抗干扰[J].华北电力技术,1995(2):21-26. 被引量:3
  • 2DLA17-91.电力设备局部放电现场测量导则[S].[S].,1991..
  • 3Bartnikas R. Partial discharges, their mechanism, detection and measurement[J]. IEEE Trans on D&EI, 2002,9(5): 763-808.
  • 4IEC60270. Parital Discharge Measurement[S], 1996.
  • 5上海松宝科技发展有限公司.JF-2001干扰判别式局部放电检测仪使用说明书[Z].上海:上海电动工具研究所,2001..
  • 6王晓蓉,胡龙龙,张冠军,严璋.局部放电测量方法及其测量回路的抗干扰研究[J].高压电器,2001,37(4):10-13. 被引量:8

共引文献3

同被引文献9

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部