摘要 In this study, a novel scaled-up hybrid acidogenic bioreactor(HAB) was designed and adopted to evaluate the performance of azo dye(acid red G, ARG) containing wastewater treatment. Principally, HAB is an acidogenic bioreactor coupled with a biocatalyzed electrolysis module. The effects of hydraulic retention time(HRT) and ARG loading rate on the performance of HAB were investigated. In addition, the influent was switched from synthetic wastewater to domestic wastewater to examine the key parameters for the application of HAB. The results showed that the introduction of the biocatalyzed electrolysis module could enhance anoxic decolorization and COD(chemical oxygen demand) removal. The combined process of HAB-CASS presented superior performance compared to a control system without biocatalyzed electrolysis(AB-CASS). When the influent was switched to domestic wastewater, with an environment having more balanced nutrients and diverse organic matters, the ARG, COD and nitrogen removal efficiencies of HAB-CASS were further improved, reaching 73.3% ± 2.5%, 86.2% ± 3.8% and 93.5% ± 1.6% at HRT of 6 hr, respectively, which were much higher than those of AB-CASS(61.1% ± 4.7%,75.4% ± 5.0% and 82.1% ± 2.1%, respectively). Moreover, larger TCV/TV(total cathode volume/total volume) for HAB led to higher current and ARG removal. The ARG removal efficiency and current at TCV/TV of 0.15 were 39.2% ± 3.7% and 28.30 ± 1.48 mA,respectively. They were significantly increased to 62.1% ± 2.0% and 34.55 ± 0.83 mA at TCV/TV of 0.25. These results show that HAB system could be used to effectively treat real wastewater. In this study, a novel scaled-up hybrid acidogenic bioreactor(HAB) was designed and adopted to evaluate the performance of azo dye(acid red G, ARG) containing wastewater treatment. Principally, HAB is an acidogenic bioreactor coupled with a biocatalyzed electrolysis module. The effects of hydraulic retention time(HRT) and ARG loading rate on the performance of HAB were investigated. In addition, the influent was switched from synthetic wastewater to domestic wastewater to examine the key parameters for the application of HAB. The results showed that the introduction of the biocatalyzed electrolysis module could enhance anoxic decolorization and COD(chemical oxygen demand) removal. The combined process of HAB-CASS presented superior performance compared to a control system without biocatalyzed electrolysis(AB-CASS). When the influent was switched to domestic wastewater, with an environment having more balanced nutrients and diverse organic matters, the ARG, COD and nitrogen removal efficiencies of HAB-CASS were further improved, reaching 73.3% ± 2.5%, 86.2% ± 3.8% and 93.5% ± 1.6% at HRT of 6 hr, respectively, which were much higher than those of AB-CASS(61.1% ± 4.7%,75.4% ± 5.0% and 82.1% ± 2.1%, respectively). Moreover, larger TCV/TV(total cathode volume/total volume) for HAB led to higher current and ARG removal. The ARG removal efficiency and current at TCV/TV of 0.15 were 39.2% ± 3.7% and 28.30 ± 1.48 mA,respectively. They were significantly increased to 62.1% ± 2.0% and 34.55 ± 0.83 mA at TCV/TV of 0.25. These results show that HAB system could be used to effectively treat real wastewater.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2016年第1期198-207,共10页 环境科学学报(英文版)
基金 financially supported by the Ministry of Environmental Protection of the People's Republic of China (Major Science and Technology Program for Water Pollution Control and Treatment) (No. 2014ZX07204-005) the National Natural Science Foundation of China (Nos. 51222812, 31370157, 21407164, 51508551) the China Postdoctoral Science Foundation (No. 2015M580140) the National Science Foundation for Distinguished Young Scholars (No. 51225802) Hundred Talents Program of the Chinese Academy of Sciences (No. 29BR2013001)
关键词 HAB(hybrid acidogenic bioreactor) Scale-up Azo dye Domestic wastewater Cyclic activated sludge system(CASS) HAB(hybrid acidogenic bioreactor) Scale-up Azo dye Domestic wastewater Cyclic activated sludge system(CASS)
  • 相关文献

参考文献28

  • 1APHA, 1998. Standard Methods for the Examination of Water and Waste Water. 20th ed. American Public Health Association/ American Water Works Association/Water Environment Federation.
  • 2Cmar, O., Ya~ar, S., Kertmen, M., Demir6z, K., Yigit, N.()., Kitis, M., 2008. Effect of cycle time on biodegradation of azo dye in sequencing batch reactor. Process. SaC Environ. Prot. 86 (6), 455-460.
  • 3Cui, D., Guo, Y.Q., Cheng, H.Y., Liang, B., Kong, F.Y., Lee, H.S., et al., 2012. Azo dye removal in a membrane-free up-flow biocatalyzed electrolysis reactor coupled with an aerobic bio-contact oxidation reactor. J. Hazard. Mater. 239-240, 2 S 7-264.
  • 4Cui, D., Guo, Y.Q., Lee, H.S., Wu, W.M., Liang, B., Wang, AJ., et al., 2014. Enhanced decolorization of azo dye in a small pilot-scale anaerobic baffled reactor coupled v~th biocatalyzed electrolysis system (ABR-BES): a design suitable for scaling-up. Bioresour. Technoh 163, 254-261.
  • 5Dong, Y., Qu, Y., He, W., Du, Y., Liu, J., Han, X., et al., 2015. A 90-liter stackable baffled microbial fuel cell for brewery wastewater treatment based on energy self-sufficient mode. Bioresour. Technol. 195, 66-72.
  • 6Donlon, B., Flores, E., Luijten, M., Swarts, H., Lettinga, G., Field, J., 1997. Detoxification and partial mineralization of the azo dye mordant orange 1 in a continuous upflow anaerobic sludge-blanket reactor. App1. Microbiol. Biotechnol. 47 (1), 83-90.
  • 7Escapa, A., San-Martin, M.I., Mateos, R., Moran, A., 2015. Scaling-up ofmembraneless microbial electrolysis cells (MECs) for domestic wastewater treatment: bottlenecks and limitations. Bioresour. Technol. 180, 72-78.
  • 8Feng, H., Zhang, X., Liang, Y., Wang, M., Shen, D., Ding, Y., et al., 2014. Enhanced removal of p-fluoronitrobenzene using bioelectrochemical system. Water Res. 60 (1), 54-63.
  • 9Heidrich, E.S., Edwards, S.R., Dolfing, )., Cotterill, S.E., Curtis, T.P., 2014. Performance of a pilot scale microbial electrolysis cell fed on domestic wastewater at ambient temperatures for a 12 month period. Bioresour. Technol. 173, 87-95.
  • 10Korneel Rabaey, G.L, Siciliano, S.D., Verstraete, W., 2003. A microbial fuel cell capable of converting glucose to electricity at high rate and efficiency. Biotechnol. Lett 25, 1531-1535.

同被引文献5

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部