期刊文献+

拉链柱支撑钢框架结构振动台试验研究 被引量:4

Shaking table test of zipper frames
原文传递
导出
摘要 为研究拉链柱支撑钢框架结构的抗震性能并对设计方法进行验证,完成了一个3层单跨1∶4缩尺比例的拉链柱支撑钢框架结构模型在24个地震作用工况下的模拟地震作用振动台试验。通过试验,得到了结构的动力特性、层间位移响应、加速度响应以及各结构构件的受力状态等。结果表明,8度多遇及设防烈度地震作用工况下,结构基本未进入塑性,试验模型振动时以第1阶模态振动为主。超9度罕遇地震作用工况下,底层支撑失稳明显,顶层支撑未见失稳。底层受拉支撑的最大轴拉力接近屈服轴力,受压支撑的屈曲后承载力约为支撑稳定承载力的30%,表明由支撑失稳产生的竖向不平衡力按受拉支撑的最小屈服承载力和受压支撑的最大屈曲承载力的30%计算是可行的。拉链柱主要通过受拉传递因支撑失稳产生的竖向不平衡力。因变形协调关系,被支撑梁可以承受一定的竖向不平衡力,在拉链柱未屈服的前提下,一般下层被支撑梁承受的竖向不平衡力要高于上层的。总体上,各构件的受力状态及传力路径与设计初衷基本一致,结构体系在模拟地震作用振动台试验中表现出了良好的抗震性能。 In order to investigate the seismic performance and verify the design method of zipper frames, a 3-story 1 : 4 scaled single-span zipper frame model was designed and tested using the shaking table under 24 different earthquake events. The dynamic properties, acceleration response, displacement response and force state of structural members were studied. The results show that, under frequent and occasional earthquake events of intensity 8, the test model does not develop plastic deformation and the dynamic performance is predominated by the first mode. Under rare earthquake events of over intensity 9, the first story brace buckles obviously and the top story brace doesn' t buckle. The maximum brace axial tension force is close to the yielding force and the brace post-buckling force is about 30% of the stability bearing capacity, indicating that the unbalanced vertical force due to brace buckling can be calculated using the yielding force of the tension brace and 30% of the stability bearing capacity of the compression brace. The unbalanced vertical force is mainly transferred by the zipper struts. Due to deformation compatibility, the braced beams also can transfer part of the unbalanced vertical force. If the zipper strut has not yielded, the unbalanced vertical force transferred by the braced beam at the lower story is larger than that at the upper story. In general, the force state and force-transferring path of the structural members are basically in accordance with the design objective and the zipper frame shows good seismic performance in the shaking table test.
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2016年第2期55-62,共8页 Journal of Building Structures
基金 国家自然科学基金项目(51208169 51178145) 河北省自然科学基金项目(E2014208115)
关键词 中心支撑钢框架结构 振动台试验 拉链柱 支撑 抗震性能 concentrically braced steel frame shaking table test zipper strut brace seismic performance
  • 相关文献

参考文献16

  • 1Chen L. Innovative bracing system for earthquake resistant concentrically braced frame structures [ D ]. Montreal, Canada: Coneordia University, 2011 : 1 - 6.
  • 2Khatib I F, Marin S A, Pisiter K S. Seismic behavior of concentrically braced steel frames [ R]. Report No. UCB/EERC-88/01. Berkeley: Earthquake Engineering Research Center, University of California at Berkeley, 1988:74-87.
  • 3GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
  • 4ANSI/AISC 341-10 Seismic provisions for structural steel buildings [ S ]. Chicago, IL : American Institute of Steel Construction, 2010.
  • 5Sabelli R. Research on improving the design and analysis of earthquake resistant steel braced frames [ R ]. The 2000 NEHRP Professional Fellowship Report. Oakland, CA : Earthquake Engineering Research Institute, 2001:2.1-2.18.
  • 6Tremblay R, Tirca L. Behavior and design of multi- story zipper concentrically braced steel frames for the mitigation of soft-story response [ C ]//Proceedings of the Conference on Behavior of Steel Structures in Seismic Areas. Naples, Italy: CRC Press, 2003: 471- 478.
  • 7Leon T R, Yang C S. Special inverted-V braeed frames with suspended zipper struts [ C ]//Proceedings of the International Workshop on Steel and Concrete Composite Construction. Taipei:Center for Research on Earthquake Engineering, 2003 : 89-96.
  • 8Schachter M, Reinhorn A M. Analytical modeling of zipper frames subjected to shaking table testing [ C ]// Proceedings of 2007 ASCE Structures Congress. Long Beach, California : Structural Engineering Research Frontiers, 2007 : 1-10.
  • 9Yang C S. Analytical and experimental study of concentrically braced frames with zipper struts [ D ]. Atlanta, US : Georgia Institute of Technology, 2006:28- 96.
  • 10Yang C S, Leon R T, Desroches R. Pushover test and analysis of a braced frame with suspended zipper struts [ J]. Journal of Structural Engineering, ASCE, 2008, 134(10): 1619-1626.

二级参考文献22

  • 1连尉安,张耀春,张文元.基于塑性应变能的钢支撑疲劳损伤评估方法[J].哈尔滨工业大学学报,2007,39(4):525-529. 被引量:4
  • 2CECS160:2004建筑工程抗震性态设计通则[S].北京:中国建筑工业出版社,2004.
  • 3Abolhassan Astaneh-Asl, Subhash C Goel, Robert D Hanson. Cyclic out-of plane buckling of double-angle bracing [J]. Journal of Structural Engineering, ASCE, 1985, 111(5): 1135--1153.
  • 4Abolhassan Astaneh-Asl. Seismic behavior and design of gusset plates [R]. Steel Tips, Structural Steel Education Council, 1998.
  • 5ANSI/AISC 341-05, Seismic provisions for structural steel buildings [S]. Chicago (IL): American Institute of Steel Construction, 2005.
  • 6Yoo Jung-Han, Lehman Dawn E, Roeder Charles W. Influence of connection design parameters on the seismic performance of braced frames [J]. Journal of Construction Steel Research, 2008, 64: 607--623.
  • 7Yoo Jung-Han, Roeder Charles W, Lehman Dawn E. Analytical performance simulation of special concentrically braced frames [J]. Journal of Structural Engineering, ASCE, 2008, 134(6): 881--889.
  • 8Lehman Dawn E, Roeder Charles W, David Herman. Improved seismic performance of gusset plate connections [J]. Journal of Structural Engineering, ASCE, 2008, 134(6): 890--901.
  • 9Socie G Ohgi G Fatigue criterion under combined stress or strains [J]. Journal of Eningeering Material and Technology, ASME, 1981, 103: 82--90.
  • 10.GB50011-2001建筑抗震设计规范[S].北京:中国建筑工业出版社,2001..

共引文献1534

同被引文献30

引证文献4

二级引证文献19