本文通过结合实例对地表水源热泵水温变化两种计算方法对比分析,结果表明采用热泵排热量直接计算法误差较大,建议工程设计时采用水温模拟法进行计算。可为地表水源热泵设计提供参考。
Based on an actual project, two methods for water temperature variation calculation of Surface Water Heat Pump (SWHP) were compared and analyzed. The result is that the error of the method using directly released heat by SWHP was bigger, and it should apply water temperature modeling method to calculate the water temperature variation. It provides a reference for SWHP project design.