摘要
脱硫吸收塔浆液品质关乎整个脱硫装置的安全运行,针对一起吸收塔浆液恶化的事件,分析了其原因并采取相应的运行措施,确保了脱硫系统的安全运行,对火电厂脱硫系统相似事故处理有借鉴意义。
The slurry quality of desulfurization absorption tower relates to the safe operation of the desulfurization unit. Through analyzing the causes of an event of absorber slurry deterioration,the corresponding operation processing countermeasures are taken,which ensure the safety operation of the FGD system. It can be used to similar accident of desulfurization system of coal- fired power plant. 。
出处
《电力科技与环保》
2015年第5期35-36,共2页
Electric Power Technology and Environmental Protection
关键词
脱硫吸收塔
浆液恶化
原因分析
对策
desulfurization absorption tower
slurry deterioration
reason analysis
countermeasure