摘要 耐爆能量是电容器的一项重要的安全性能指标,它表示电容器在极间短路时,外部电路(包括电容器自身的储能)注入故障点而不使其外壳发生爆裂的能量的限值,即是对电容器外壳强度的一个安全要求。通过几种常见的同容量不同接线和布置方式下的耐爆能量来对比分析说明通过合理的接线和布置可防止装置产生的最大耐爆能量大于15 k J,避免发生重大事故。 The energy without rupture of power capacitor is an important safety index, representing energy limit which, in case of inter-pole short circuit of capacitor, could not cause the capacitor case to rupture when the external circuit is injected into the fault point (including the charge of capacitor itself). It is a requirement to the safe strength of capacitor case. It is shown through comparison and analysis of energy without rupture at several common different wiring and layout of the capacity that the maximum energy without rupture generated by the device by way of reasonable wiring and layout exceeds 15 kJ,which can avoid major fault.
作者 石彬 王慧
出处 《电力电容器与无功补偿》 北大核心 2015年第4期32-35,40,共5页 Power Capacitor & Reactive Power Compensation
关键词 耐爆能量 故障点 等效容量 击穿 energy without rupture fauh point equivalent capacity breakdown
  • 相关文献

参考文献15

  • 1GB50227-2008并联电容器装置设计规范[S].
  • 2GB/T 11024.3-2001标称电压1 kV以上交流电力系统用并联电容器第3部分:并联电容器和并联电容器组的保护[S].
  • 3谷定燮,李小玲,莫青,王善钧,王子春.并联电容器组向故障电容器放电的能量研究[J].电力电容器,1991(2):1-5. 被引量:15
  • 4GB3111-1997.高压输变电设备的绝缘配合[S].[S].,..
  • 5中国国家电网公司.高压并联电容器装置技术标准[Z].
  • 6GB50060-20083-110kV高压配电装置设计规范[S].2008.
  • 7DL/T584-2007 3-110kV电网继电保护装置运行整定规程[S].
  • 8中国电力科学研究院.特高压装置电容器组主要技术要求[Z].
  • 9GB/T12802-1996.电容器用聚丙烯薄膜[S].[S].,..
  • 10倪学锋.问与答[J].无功补偿装置,2003(1):23-24.

二级参考文献35

共引文献228

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部