上颌双侧游离端活动义齿连接体的激光全息应力分析 被引量:7

Holographic Stress Analysis of Maxillary Bilateral Free-end Removable Partial Denture Connectors
暂未订购
导出
摘要 本文用激光全息干涉度量术对双侧游离端部分活动义齿连接体在各种工作状态下受力情况进行定性分析,以期了解义齿本身受力后的变形情况,为设计义齿提供结构力学的参考。实验所得的全息干涉条纹图说明,常规设计的四种不同连接体在双侧和单侧加力时各有其不同的变形,干涉条纹变化可以看出变形大小、应力传递和分布,以及基板末端等区粘膜上的受力情况。结果证明,全塑基板连接体变形较大,而前塑加弯制后腭杠型变形较小,相应的粘膜受力也较小。 The purpose of this study is to investigate the deformations of the connectors by meansof the double-expo(?)ure holographic interferometry,and to get qualitative analysis.The authors selected four types of connectors.Each connector shows a dissimilar fringe.These interferential fringes exhibit the degree,tranfer and distribution of stress on theconnectors and the distal supporting tissue.The result showed that the deformation on the No.2 type connector is smaller.It couldbe used as reference in structural mechanics for denture design.
出处 《华西口腔医学杂志》 CAS CSCD 北大核心 1989年第2期65-68,共4页 West China Journal of Stomatology
  • 相关文献

参考文献2

  • 1汪文骏,张成藩,杨云曙,徐鹤廷.游离端活动部分义齿的电测法应力分析(三)——结论及临床意义[J]口腔医学,1985(02).
  • 2朱希涛,白沁,周辛庚,章玮宝,刘春阳.完全固定桥与半固定桥受力状况的激光全息分析[J]中国生物医学工程学报,1985(01).