摘要 空间分辨率是CT图像质量的两项重要性能指标,其测试工作也是CT设备性能测试的重要内容。本文提出工业CT系统空间分辨率常用的两种测试方法,编写基于圆盘法的空间分辨率测试软件,并结合测试软件进行空间分辨率的测试。两种测试方法的对比实验在三套工业CT系统中开展,并在相同试验条件下实施、数据采集、计算和分析。结果发现,在三套工业CT设备测试结果中,基于圆盘法的测试结果要明显低于基于标准中规定的线对卡测试方法测试结果,本文根据傅立叶变换讨论两种测试方法测试结果产生差异的原因。 Spatial resolution is the two most important parameters of CT image quality, and the test work of this parameter is main part of CT scanner's quality assurance. This paper represents two methods, which were dedicated for the assessment of spatial resolution in CT system, and analysis spatial resolution of CT system by using software tools. The comparative study of the two methods was carried out in 3 ICT systems under the same experiment condition. We found that the test result of disc phantom method is significantly higher than the result of practical-MTF method, and then the relationship between the test results of the two methods was discussed.
出处 《CT理论与应用研究(中英文)》 2015年第3期393-399,共7页 Computerized Tomography Theory and Applications
基金 国家自然科学基金(61471411)
关键词 空间分辨率 圆盘法 线对卡法 spatial resolution disc phantom method practical-MTF method
  • 相关文献

参考文献8

  • 1Steve Smith. The scientist and engineer's guide to digital signal processingEM], ied. American: California Technical Publishing, 1998: 423-430.
  • 2张朝宗.工业CT技术参数对性能指标的影响——兼谈如何选择工业CT产品[J].无损检测,2007,29(1):48-52. 被引量:22
  • 3ASTM E 1695-1995 (Reapproved 2013). Standard test method for measurement of CT system performanceS]. USA, ASTM Committee of Standard, 2000.
  • 4占杰,余晓锷.CT空间分辨率自动检测的研究与实践[J].CT理论与应用研究(中英文),2006,15(2):43-46. 被引量:8
  • 5刘力,张英平.工业CT中MTF曲线测量的ASTM方法[J].无损检测,2007,29(7):399-401. 被引量:2
  • 6Tarraf Torfeh, Stephane. Software tools dedicated for a automatic analysis of the CT scanners quality control' s images[J]. Hal 00326646, 2008: 1-4.
  • 7Tarraf rorfeh, Stephane. Evaluation of two software tools dedicated for an automatic analysis of the CT scanner images spatial resolution[J]. 29th Annual International Conference of the IEEE, 2007: 3910-3913.
  • 8国防科学技术工业委员会.GJB5312-2004.工业射线层析成像(CT)检测[S].北京:国防科工委军标出版发行部,2004.

二级参考文献7

  • 1胡曙光,昌仁民,冯小刚,康立丽,林意群,张雪林.CT的MTF测量和评价[J].中国医学物理学杂志,1997,14(1):30-32. 被引量:7
  • 2Andrew D.A.Maidment,Michael Albert.Conditioning data for calculation of the modulation transfer function[J].Med Phys.2003 Feb;30(2):248-53.
  • 3Samei E,Flynn MJ,Reimann DA.A method for measuring the presampled MTF of digital radiographic systems using an edge test device[J].Med Phys.1998 Jan;25(1):102-13.
  • 4Boone JM,Seibert JA.An analytical edge spread function model for computer fitting and subsequent calculation of the LSF and MTF.[J].Med Phys.1994 Oct;21(10):1541-5.
  • 5ASTM E 1695-1995(Reapproved 2001) Standard Test Method for Measurement of CT System Performance[S].
  • 6闫罡,童双立,孙璐,贾绍田.X-CT机空间分辨率测试规范的探讨[J].CT理论与应用研究(中英文),1998,7(1):38-42. 被引量:7
  • 7冯晓刚,洪德明,余晓锷,林木炎.多层面螺旋CT机的应用质量检测与结果分析[J].中国医学计算机成像杂志,2001,7(5):352-354. 被引量:7

共引文献28

同被引文献43

引证文献7

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部