期刊文献+

循环水养殖旋转式生物流化床生物过滤功能 被引量:12

Biofiltration of cyclo-bio fluidized sand bed in recirculating aquaculture system
在线阅读 下载PDF
导出
摘要 生物过滤是循环水养殖水处理的关键,生物过滤功能启动以及操作条件直接影响到生物过滤的效果。该文以实验室规模旋转式生物流化床为研究对象,采用自然挂膜法研究海水和淡水生物过滤功能的启动;设置了3个膨胀率50%、75%、100%和4个C/N0、0.5、1.0、2.0,研究其对旋转式生物流化床处理养殖污水效率的影响。结果表明:1)以氨氮和亚硝态氮浓度降低并稳定为判断标准,淡水和海水系统旋转式生物流化床生物过滤功能启动完成分别需要47和60 d;2)污水处理效率随膨胀率增大而提高,该研究膨胀率为100%时处理效率最高,总氨氮转换率高达881 g/(m3·d);3)C/N增大,抑制生物膜的硝化功能,污水处理效果变差,C/N大于2.0时污水处理效果显著变差。该研究可为旋转式生物流化床在应用过程中生物过滤功能的启动和日常操作管理提供技术指导。 A lab-scale cyclobio fluidized sand biofilter was designed to study biofiltration in recirculating aquaculture systems. First, the biofiltration start was studied separately in fresh water and seawater recirculating aquaculture systems. Second, the influence of different operation conditions on water treatment were studied by natural membrane-forming, including three bed expansions(50%, 75% and 100%) and four carbon nitrogen ratios(0, 0.5, 1 and 2). A synthetic substrate solution was continuously fed into the tanks after measuring of water quality every time. The results showed that the total ammonia-nitrogen concentration was decreased, fluctuating lightly in later period. The nitrite-nitrogen concentration was in a shape of clock, increasing quickly first and keeping the maximum for days then decreasing quickly, fluctuating lightly in later period. Not only ammonia-nitrogen and nitrite-nitrogen concentrations, but also the stability of water quality should be as the criteria of completion judgement of biofiltration start. In these conditions, biofiltration start of cyclobio fluidized biofilter were 47 days in fresh water system and 60 days in seawater system. Besides, we found that the cyclobio fluidized biofilter had little help in removing phosphorous, maybe because dissolved oxygen was always more than 6 mg/L in system. The nitrate-nitrogen concentration was increased on the whole. However, high nitrite-nitrogen concentration may harm fish health. To avoid that, there were two control methods: exchanging some new water to system every day, or adding denitrification equipment to recirculating aquaculture systems. Meanwhile, the results of operation conditions showed that the maximum load of system was separately 2.5, 3.0 and 3.5 mg/L with different bed expansions 50%, 75% and 100%. And the removal efficiency of total ammonia-nitrogen increased and the nitrite-nitrogen concentration decreased with the enhancement of bed expansion. The efficiency of ammonia-nitrogen was the highest and the load of system was the largest under 100% bed expansion in this study, while the volumetric total ammonia nitrogen conversion rate was 881g/(m3·d). Besides, inhibition of organic on nitrification was observed. The ammonia-nitrogen, nitrite-nitrogen and COD concentrations were increased with the enhancement of ratios of carbon and nitrogen. Especially, water quality went bad obviously when ratios of carbon and nitrogen was more than 2.0. The ammonia-nitrogen and nitrite-nitrogen even reached to lethal or medial lethal concentrations of some fishes. The possibility was that heterotrophic microorganisms breed quickly with the enhancement of ratios of carbon and nitrogen and autotrophic nitrifying bacteria was embedding and died absenting of oxygen. This research can provide a reference for starting, operation and management of cyclobio fluidized biofilters in production.
出处 《农业工程学报》 EI CAS CSCD 北大核心 2015年第3期249-254,共6页 Transactions of the Chinese Society of Agricultural Engineering
基金 "十二五"国家科技支撑项目(2011BAD13B04)
关键词 水产养殖 生物过滤 海水 旋转式生物流化床 生物过滤功能启动 膨胀率 C/N aquaculture biofiltration seawater cyclo-bio fluidized sand beds starting bed expansion C/N
  • 相关文献

参考文献25

  • 1Heinen J M, Hankins J A, Weber A L, et al. A semi-closed recirculating water system for high density culture of rainbow trout [J]. Progressive Fish Culturist, 1996, 58:11-22.
  • 2Summerfelt S T, Davidson J, Helwig N. Evaluation of a full-scale cycloBio fluidized sand biofilter in a coldwater recirculating system [C]// Proceedings of the Fifth International Conference on Recirculating Aquaculture, Virginia Polytechnic Institute and State University, Roanoke, VA, 2004: 227-237.
  • 3Summerfelt S T, Wade E M. Fluidized-sand biofilters installed at two farms [J]. Recirc Today, 1998, 1(1): 18-21.
  • 4Timmons M B, Helwig N, Summerfelt S T. The Cyclone sand biofilter: A new design concept and field evaluation [C]// Proceedings of the Third International Conference on Recirculating Aquaculture, Virginia Polytechnic Institute and State University, Roanoke, VA, 2000:222 - 226.
  • 5Summerfelt S T. Design and management of conventional fluidized-sand biofilters [J]. Aquaculral Engineering, 2006, 34: 275-302.
  • 6Davidson J, Helwig N, Summerfelt S T. Fluidized sand biofilters used to remove ammonia, biochemical oxygen demand, total coliform bacteria, and suspended solids from an intensive aquaculture effluent[J]. Aquacultural Engineering, 2008, 39: 6-15.
  • 7张海耿,吴凡,张宇雷,宋奔奔,宋红桥,倪琦.涡旋式流化床生物滤器水力特性试验[J].农业工程学报,2012,28(18):69-74. 被引量:12
  • 8LIU Yao,SONG Xiefa,LIANG Zhenlin,PENG Lei.Application of CFD Modeling to Hydrodynamics of CycloBio Fluidized Sand Bed in Recirculating Aquaculture Systems[J].Journal of Ocean University of China,2014,13(1):115-124. 被引量:8
  • 9柳瑶,宋协法,梁振林,廉大晓,周游.工厂化循环水养殖中生物流化床的流化特性研究[J].中国海洋大学学报(自然科学版),2014,44(1):41-45. 被引量:6
  • 10Liu Y, Capdeville B. Kinetic behaviors of nitrifying biofilm growth in wastewater nitrification process[J]. Environmental Science Technology, 1994, 15(11): 1001-1013.

二级参考文献90

共引文献141

同被引文献187

引证文献12

二级引证文献78

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部