期刊文献+

燃气轮发电机励磁变高压侧电流互感器的选择应用 被引量:1

Selection of HV Current Transformers of Gas Turbine Generator Excitation Transformer
在线阅读 下载PDF
导出
摘要 燃气轮发电机励磁变压器高压侧套管电流互感器,其准确限值系数由机端短路电流和所选电流互感器的一次侧额定电流两者决定。励磁变高压侧短路电流非常大,而其额定电流又比较小,因此按常规方式难以选到满足要求的励磁变高压侧电流互感器。燃气轮发电机差动保护采用不完全纵差保护,因此可以利用此方法来降低励磁变高压侧电流互感器的准确限值系数。此外,利用电流互感器准确限值系数与二次侧负荷的关系,可以进一步提高电流互感器的准确限值系数,满足工程的需要。 Accuracy limit factor of HV bushing current transformers of gas turbine generator excitation transformer is decided by both short circuit current and primary side rated current of the selected current transformer. Short-circuit current of excitation transformer HV side is very large, and the rated current is small, so it is very difficult to meet the requirements by conventional way. Gas turbine generator adopt incomplete differential protection, The incompete differential protection is adopted in gas turbine generator, so this method can be used to reduce accuracy limit factor of HV bushing current transformers. In addition, using the relationship between accuracy limit factor and the secondary side load can improve the accuracy limit factor to the requirement.
作者 蔡军
出处 《东方电气评论》 2015年第2期72-75,共4页 Dongfang Electric Review
关键词 燃气轮发电机 准确限值系数 不完全纵差保护 额定二次极限电动势 高压侧电流互感器 gas turbine generator accuracy limit factor incomplete differential protection rated secondary limiting e. m. f HV currenttransformer
  • 相关文献

参考文献3

二级参考文献8

  • 1齐春.发电机采用自并励励磁系统的保护问题[J].电气设计技术,1999,(2):36-36.
  • 2.GB14285-93.继电保护和安全自动装置技术规程[S].,1993..
  • 3.DL/T684-1999.大型发电机变压器继电保护整定导则[S].,1999..
  • 4陈学庸.机端励磁变压器保护方式讨论[J].电气设计技术,1997,(1):31-31.
  • 5.DI/T650-1988.大型汽轮发电机自并励系统技术条件[S].,1998..
  • 6国家发展和改革委员会.DI/T 866—2004电流互感器和电压互感器选择及计算导则[S].北京:中国电力出版社,2004.
  • 7国家经济贸易委员会.DL/T 5153—2002火力发电厂厂用电设计技术规定[S].北京:中国电力出版社,2002.
  • 8盛和乐,袁季修,秦应力,等.中压电流互感器及继电保护装置联合试验研究报告[R].北京:国电华北电力设计院工程有限公司,北京四方继保自动化有限公司.大连;大连第一互感器厂,2004.