期刊文献+

光纤光栅传感技术在翻车机结构健康监测系统的应用研究 被引量:1

Study on application of fiber bragg grating sensor technology in monitoring system for tippler structure
在线阅读 下载PDF
导出
摘要 由于光纤光栅传感器具有抗电磁干扰、尺寸小、容量大、准分布式测量,并且可以实现远距离长期监测与传输的特点,其在结构健康安全监测中得到日益广泛应用。文中论述了在大型装卸设备翻车机中引入结构健康安全监测的必要性,概述了光纤光栅传感技术的基本原理,并以翻车机为例,介绍结构健康安全监测系统的应用及关键技术,包括温度补偿、基于有限元分析的测点分布、数据采集与处理和安全预报警。 Since the fiber bragg grating sensor has the advantages of anti-electromagnetic interference, compact size, large capacity, quasi-distributed measurement, and can realize long-distance long-term monitoring and transmission, it is widely used in structural safety monitoring. The paper discusses the necessity of introducing structural safety monitoring into the large-scale handling equipment tipper, summarizes the basic principle of the fiber bragg grating sensor technology, and introduces application and critical technologies of the structural safety monitoring system with the tippler as an example, such as temperature compensation, distribution of measuring points based on finite element analysis, data acquisition and processing, and safety alarm.
机构地区 武汉电力设备厂
出处 《起重运输机械》 2015年第5期114-117,共4页 Hoisting and Conveying Machinery
关键词 翻车机 光纤光栅传感技术 健康监测 tipper fiber bragg grating sensor technology health monitoring
  • 相关文献

参考文献2

二级参考文献11

  • 1郭明金,姜德生,袁宏才,干维国.不同粘贴方式的光纤光栅压力传感器的研究[J].激光与红外,2005,35(6):417-419. 被引量:7
  • 2陈明璐.海洋平台损伤识别与定位方法及模型试验研究[D].镇江:江苏科技大学,2009.
  • 3Yun-Jiang Rao. In-fiber Bragg grating sensors[J]. Mcas.Sci.Technol 1997,8: 355-375.
  • 4Putnam M A.. Williams G M:Friebele E J:Fabrication of tapered,strain_gradient chirped fiber Bragg gratings[J]. Electron Lett,1995.31: 309.
  • 5Udd E. Fiber Optical Smart Structures[M]. John Wiley&Sons. 1995.
  • 6Proceedingson OFS-13(13^th International Conferenceon Optical Fiber Sensors)[Z]. Korea. 1999:285-291.
  • 7Smart Sructures and Materials [J]. SPIE's Proceedings. 2000, 4073:186-191.
  • 8Applications of Optical-Fiber Sensors[J]. SPIE's Proceedings. 2000.4074: 361-366.
  • 9刘晖,瞿伟廉,李功标,肖纯.光纤光栅传感系统在结构损伤识别中的应用[J].应用基础与工程科学学报,2009,17(3):395-401. 被引量:9
  • 10刘乙君,黄晨光.轴对称壳体结构损伤识别方法研究[J].力学与实践,2010,32(5):50-54. 被引量:1

共引文献20

同被引文献4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部