摘要 目的:通过比较Pentacam测量的可疑房角关闭患者行激光周边虹膜切除术前后各项参数,探讨评价前房形态改变的敏感参数。方法:诊断为可疑房角关闭并接受激光周边虹膜切除术治疗的患者33例60眼。患者术前及术后1d行Pentacam检查,观察前房各项参数在激光前后的变化,进行配对t检验。结果:与术前相比较,中央前房深度差异无统计学意义,周边前房深度明显加深,差异有统计学意义;前房容积明显增加,差异有统计学意义。前房夹角变宽,从治疗前的(22.26°±5.18°)增加为治疗后的(26.42°±5.20°),差异有统计学意义。结论:激光周边虹膜切除术可以显著增加可疑房角关闭患眼的周边前房深度和前房容积,周边前房深度和前房容积可作为评价前房形态改变的敏感参数。 AIM:To investigate the sensitive parameters of the anterior chamber changes with Pentacam anterior segment analysis system before and after laser peripheral iridectomy (LPI) in primary angle-closure suspetive (PACS). METHODS: Sixty eyes of 33 PACS patients were enrolled in this study. Pentacam examination was performed before and 1d after LPI to measure the central anterior chamber depth ( CACD ) , the peripheral anterior chamber depth ( PACD ) , the anterior chamber volume ( ACV) and the peripheral anterior chamber angle ( ACA) . Statistical analysis used paired t test. RESULTS: There was no statistical significance on the changes of ACD. PACD and ACV increased significantly between before and 1d after LPI. ACA was widened from (22. 26o±5. 18o) to (26. 42o±5. 20o), which were increased significantly between before and 1d after LPI. CONCLUSION: LPI can deepen the PACD and increase the ACV in PACS. PACD and ACV are the sensitive parameters of the anterior chamber changes with Pentacam anterior segment analysis system.
出处 《国际眼科杂志》 CAS 2015年第5期908-910,共3页 International Eye Science
关键词 可疑房角关闭 激光 虹膜周切术 Pentacam Pentacam anterior segment analysis system primary angle-closure suspect laser iridectomy
  • 相关文献

参考文献2

二级参考文献14

  • 1孙兴怀,嵇训传.原发性慢性闭角型青光眼临床规律探讨[J].中华眼科杂志,1993,29(2):76-82. 被引量:20
  • 2王宁利,周文炳,叶天才,吴中耀,刘华.原发性闭角型青光眼的临床研究[J].中华眼科杂志,1995,31(2):133-136. 被引量:103
  • 3Hema Shankar,Deepa Taranath,Chandramalar T. Santhirathelagan,Konrad Pesudovs.Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements[J]. Journal of Cataract & Refractive Surgery . 2008 (1)
  • 4Rajesh S. Kumar,Mani Baskaran,Paul T.K. Chew,David S. Friedman,Swati Handa,Raghavan Lavanya,Lisandro M. Sakata,Hon-Tym Wong,Tin Aung.Prevalence of Plateau Iris in Primary Angle Closure Suspects[J]. Ophthalmology . 2008 (3)
  • 5Julia C. Talajic,Mark R. Lesk,Mélissa Nantel-Battista,Paul J. Harasymowycz.Anterior Segment Changes After Pilocarpine and Laser Iridotomy for Primary Angle-Closure Suspects With Scheimpflug Photography[J]. Journal of Glaucoma . 2013 (9)
  • 6Monisha E Nongpiur,Judy YF Ku,Tin Aung.Angle closure glaucoma: a mechanistic review[J]. Current Opinion in Ophthalmology . 2011 (2)
  • 7Ya Xing Wang,Liang Xu,Hua Yang,Jost B. Jonas.Prevalence of Glaucoma in North China: The Beijing Eye Study[J]. American Journal of Ophthalmology . 2010 (6)
  • 8ShuningLi,HongtaoWang,DapengMu,JingFu,XiaozhenWang,JianWang,NingliWang.Prospective evaluation of changes in anterior segment morphology after laser iridotomy in Chinese eyes by rotating Scheimpflug camera imaging[J]. Clinical & Experimental Ophthalmology . 2010 (1)
  • 9Mingguang He,David S. Friedman,Jian Ge,Wenyong Huang,Chenjin Jin,Pak Sang Lee,Peng T. Khaw,Paul J. Foster.Laser Peripheral Iridotomy in Primary Angle-Closure Suspects: Biometric and Gonioscopic Outcomes[J]. Ophthalmology . 2007 (3)
  • 10Tanja M. Rabsilber,Ramin Khoramnia,Gerd U. Auffarth.Anterior chamber measurements using Pentacam rotating Scheimpflug camera[J]. Journal of Cataract & Refractive Surgery . 2006 (3)