摘要 根据多馈入短路比(multi-infeed short circuit ratio,MISCR)和多直流相互作用因子(multi-infeed interaction factor,MIIF)定义,考虑电力系统元件外特性影响,建立了仅包含换流母线电压变量的直流外特性模型。在此基础上,推导出考虑直流系统影响的交直流系统潮流雅可比矩阵修改元素解析函数。研究了直流系统外特性与电压扰动之间的关系,针对传统MISCR工程计算中面临实际问题,提出考虑直流系统外特性的MISCR实用计算方法,克服了传统计算方法难以适用于复杂大电网、并同时考虑电力系统元件特性影响的困难。研究算例比较表明,直流系统外特性对MISCR计算结果影响明显。 According to the definitions of multi-infeed short circuit ratio (MISCR) and multi-infeed interaction factor (MIIF), with the influence of external characteristics of power system elements, the DC characteristics model which only contains converter bus voltage variables was established in this paper. Based on the model, the elements in power flow Jacobian matrix of AC/DC system influenced by DC system were deduced. The relationship between voltage disturbance and DC external characteristics was studied. Then, for the traditional MISCR calculation method, considering the characteristics of DC system, the practical calculation method for MISCR was proposed, which overcomes difficulties of the traditional method applying to the large scale complex power grid and considering the influence of power system elements. Research examples show that the external characteristic of DC system has significant effect on the MISCR results.
出处 《中国电机工程学报》 EI CSCD 北大核心 2015年第9期2143-2151,共9页 Proceedings of the CSEE
关键词 直流系统 多直流相互作用因子 多馈入短路比 无功功率 DC system multi-infeed interaction factor(MIIF) multi-infeed short circuit ratio (MISCR) reactivepower
  • 相关文献

参考文献12

  • 1Hansen A, Havemann H. Decreasing the commutation failure frequency in HVDC transmission systems[J]. IEEE Transactions on Power Delivery, 2000, 15(3): 1022-1026.
  • 2Dems L H A, Andersson G. Use ot partlclpaton factors m modal voltage stability analysis of multi-infeed HVDC systems[J]. IEEE Transactions on Power Delivery, 1998, 13(1): 203-211.
  • 3Carson W T, Power system voltage stability[M] China Electric Power Press, 2002: 139.
  • 4徐梅梅,李兴源,白加林,贺洋,刘建.交直流并联系统的换流母线电压稳定性分析[J].电力系统自动化,2009,33(7):6-10. 被引量:28
  • 5Denis L H A. Voltage and power interactions in multi-infeed HVDC systems[EB/OL]. [2007-05-01 ]. http: //www.eeh.ee.ethz.ch/uploads/tx_ethpublications/Voltage_ and_Power Interaction_Report.pdf.
  • 6Kunder P. Power sNstem stability and control[M]. Beijing: China Electric Power Press, 2002.. 35 !-354.
  • 7Paulo Fischer de Toledo, Bemt B, Gunnar A. Multiple infeed short circuit ratio-aspects related to multiple HVDC into one AC network[C]//IEEE/PES Transmission and Distribution Conference & Exhibition. Dalian, China: IEEE, 2005: 1-7.
  • 8Gonzalez J W, Herold C, Retzmann G, et al. Feasibility of HVDC for very weak AC systems with SCR below 1.5[J]. IEEE Power Electronics and Motion Control Conference, 2006, 1522-1527.
  • 9CIGRE Working Group B4.41. Systems with multiple DC infeed[R]. France: CIGRE, 2008.