期刊文献+

弹光调制非线性光程差干涉信号频压转换研究 被引量:1

Frequency-to-voltage conversion for nonlinear optical path difference interferogram in photoelastic modulator
在线阅读 下载PDF
导出
摘要 弹光调制器调制产生的干涉信号存在非线性的光程差,为研究其频率特性及光程差,利用Matlab软件对干涉信号的频率及非线性的光程差进行软件仿真,设计频压转换电路,实现干涉信号频率到电压信号的转换。实验表明,通过频压转换的干涉信号,可以准确测量并计算出因晶体发热、环境温度改变及中心频率漂移造成的不稳定光程差,且光谱的频率及光程差变化量的计算速度也提高了近40%。 The interference signals produced by a photoelastic modulator have nonlinear optical path difference. In order to study the frequency characteristic and the optical path difference of the signals,a frequency-to-voltage conversion of the interference signals is presented. First,the frequency and the nonlinear optical path difference of interference signals are simulated using Matlab software,and then a frequency-to-voltage converter circuit is designed to achieve the conversion from frequency to voltage signal. Experiments show that the converted interference signals can be accurately measured and can be used to calculate the instable optical path difference caused by heat generation of crystal,ambient temperature changes and center frequency drift. The rapid calculation in frequency and the optical path difference of the spectrum is improved by nearly 40%.
出处 《济南大学学报(自然科学版)》 CAS 北大核心 2015年第2期138-141,共4页 Journal of University of Jinan(Science and Technology)
基金 国家自然科学基金(61127015)
关键词 弹光调制 频率 光程差 频压转换 photoelastic modulator frequency optical path difference frequency-to-voltage conversion
  • 相关文献

参考文献10

二级参考文献50

  • 1赵高峰,阳爱民,胡运发.一种新型PID决策模糊控制器的设计与实现[J].计算机工程,2004,30(12):158-161. 被引量:4
  • 2曾爱军,王向朝,李代林,黄立华,董作人.精确标定光弹调制器的新方法[J].光学学报,2005,25(6):799-802. 被引量:10
  • 3王劲松.PLC的远距离通信方案[J].自动化技术与应用,2006,25(10):87-88. 被引量:2
  • 4吴文秀.一种利用V/F和F/V转换器实现远距离隔离传输的实用电路[J].长江大学学报(自科版)(上旬),2006,3(4):110-111. 被引量:11
  • 5KRAUSE K M, GENEST J. Impact of interferometer optical path difference speed profile on the Fourier-transform - spectrometry derived spectrum of a telecommunications signal [J].Appl Opt ,2006,45(19) : 4684-4694.
  • 6MENG Jiang, ZU Guang guan. Multiplexing scheme for self- interfering long-period fiber gratings using a low-coherence reflectometry[J], leee Sensors Journal, 2007,28 ( 31 ) : 1283- 1286.
  • 7EVA A, SARA C, RALF B. Modified point diffraction interferometer for inspection and evaluation of ophthalmic components[J]. OSA, 2006,26(3) :632-637.
  • 8GHAZEL M, TRABOULSEE A, WARD R K. Optimal filter design for multiple sclerosis Lesions segmentation from regions of interest in brain MRI[J]. Ieee Sensors Journal, 2006, 10 (11):1- 5.
  • 9LUCEY P G, HORTON K, WILLIAMS T. High-performance Sagnac interferometer using cooled detectors for infrared LWIR hyperspectral imaging[C]. SPIE,2007,6546(4) : 1- 7.