期刊文献+

聚乳酸医用缝合线捻度稳定度与线密度的测试及优化 被引量:1

Testing and Optimization of Twist Stability and Linear Density of Polylactic Acid Monofilament Surgical Suture
原文传递
导出
摘要 捻度稳定度和线密度对单丝型医用缝合线有较大影响。通过正交试验的方法,设计不同的捻因数、热定形温度与热定形时间,对聚乳酸长丝进行加捻与热定形,对处理后的聚乳酸长丝捻度稳定度以及线密度进行测量,结果表明:当捻因数为285、热定形温度为60℃、热定形时间为15 min时,聚乳酸缝合线的综合性能最佳。 Twist stability and linear density had great influence on the monofilamen suture. By the orthogo- nal test, polylactic acid monofilament was twisted and heated setting through the different twist factor, heat setting temperature and time. Then, the twist stability and linear density were measured. The results showed that: when the twist factor was 285, heat setting temperature was 60 ℃, heat setting time was 15 min, polylactic acid sutures had the best comprehensive performance.
出处 《合成纤维》 CAS 2015年第1期19-21,共3页 Synthetic Fiber in China
基金 山西省大学生创新实验项目(2013067) 太原理工大学校基金项目(2012L074) 太原理工大学校青年科学基金项目(2013T020 2013T021 2013T022)
关键词 聚乳酸纤维 医用缝合线 线密度 捻度稳定度 正交试验 polylactic acid fiber, surgical suture, linear density, twist stability, orthogonal test