舌向整体移位设计量对隐形矫治力影响的研究 被引量:7

Effects of amount of activation for lingual bodily movement of maxillary central incisor on orthodontic force generated by thermoplastic aligners
原文传递
导出
摘要 目的 利用传感器芯片对不同移位设计量的隐形矫治器所产生的矫治力进行测量,探讨移位设计量对隐形矫治力及其衰减的影响,为临床正畸矫治设计提供参考.方法 选用厚度1.0mm的热压膜材料(Erkodent,德国)压制右上中切牙舌向移位设计量分别为0.2、0.3、0.4、0.5和0.6mm的隐形矫治器,利用隐形矫治微型测力系统测量矫治器产生的矫治力并观察其在2周内的衰减情况.结果 移位设计量为0.2、0.3、0.4、0.5、0.6mm的矫治器所产生的矫治力的平均值分别为8.047、9.250、10.189、11.821、12.247N.在矫治器戴入的最初8h矫治力衰减迅速,之后衰减缓慢直至第4天起矫治力维持在较为平稳的水平.结论 随矫治器移位设计量的增加,隐形矫治器产生的矫治力也相应增加.推荐上中切牙舌向整体移动的移位量设计不应超过0.5mm.患者在佩戴每副矫治器的最初4天应尽量全天佩戴. Objective To measure orthodontic force generated by different amounts of activation of lingual invisible aligners with the use of the Micro-stress sensor and explore the possible influences of activation amounts on the orthodontic force.Methods 1.0 mm thickness thermoplastic materials were selected to manufacture the aligners with 0.2 mm,0.3 mm,0.4 mm,0.5 mm and 0.6 mm activation for lingual bodily maxillary central incisor movement.The orthodontic force delivered by the thermoplastic aligners was measured using micro-stress sensor measurement system for invisible orthodontic technique,and monitored force attenuation within 2 weeks.Results The average orthodontic force generated by the aligners with 0.2 mm,0.3 mm,0.4 mm,0.5 mm and 0.6 mm activation was 8.047 N,9.250 N,10.189 N,11.821 N and 12.247 N relatively.All aligners demonstrated a quick decreasing strain at first 8 hours,then the strain decreased slowly and plateaued from day 4.Conclusions As amount of activation increases,orthodontic force generated by the invisible orthodontic appliances also increases.It is recommended that the amount of activation should not exceed 0.5mm for lingual bodily movement of maxillary central incisor.Each aligner should be worn for close to 24 hours per day in the first 4 days.
出处 《中华口腔正畸学杂志》 2014年第4期200-203,共4页 Chinese Journal of Orthodontics
基金 国家自然科学基金(81100773) 国家自然科学基金(81271184) 2011年北京市科技新星(2011084)
关键词 隐形矫治器 矫治力 移位量 衰减 Thermoplastic aligner Orthodontic force Amount of activation Attenuation
  • 相关文献

参考文献19

  • 1Rosvall MD, Fields HW, Ziuchkovski J, et al. Attractiveness, acceptability, and value of orthodontic appliances[J]. Am J Orthod Dentofacial Orthop, 2009 , 135 (3):276. e1-12.
  • 2Schaefer I,Braumann B. Halitosis, oral health and quality of life during treatment with Invisalign and the effect of a low-dose chlorhexidine solution[J]. J Orofac Orthop,2010, 71(6) :430-441.
  • 3H6nn M1, Goz G. A premolar extraction case using the Invisalign system [J]. J Orofac Orthop, 2006, 67 (5): 385-394.
  • 4Womack WR. Four-premolar extraction treatment with Invisalign[J]. J Clin Orthod, 2006,40(8) : 493- 500.
  • 5Frongia G, Castroflorio T. Correction of severe toothrotations using clear aligners.- a case report[J]. Aust Orthod J,2012,28(2) :245-249.
  • 6Zhang N, Bai Y, Ding X, et al. Preparation and characterization of thermoplastic materials for invisible orthodontics[J]. Dent Mater J, 2011,30(6) : 954-959.
  • 7白玉兴,王凡,祁鹏,周洁珉,厉松,岐红恩.无托槽隐形矫治技术与固定矫治技术尖牙远中移动的有限元对比分析[J].现代口腔医学杂志,2009,23(3):261-264. 被引量:26
  • 8Kohda N, Iijima M, Muguruma T, et al. Effects of mechanical properties of thermoplastic materials on the initial force of thermoplastic appliances[J]. Angle Orthod, 2013,83 (3) :476-483.
  • 9Fang D,Zhang N,Chen H,et al. Dynamic stress relaxation of orthodontic thermoplastic materials in a simulated oral environment[J]. Dent Mater J,2013,32(6):946-951.
  • 10任超超,白玉兴,王喆垚,张敏.无托槽隐形矫治微型测力系统的建立[J].中华口腔医学杂志,2011,46(10):600-603. 被引量:9

二级参考文献19

  • 1吴丽萍,梁傥,李洪,刘磊,吴宏.错合畸形矫治过程中初始应力分析[J].口腔医学纵横,1994,10(2):99-101. 被引量:3
  • 2王邦康.口腔正畸矫治方法的新进展——无托槽隐形矫治器的研究与展望[J].北京口腔医学,2005,13(1):2-5. 被引量:29
  • 3王凡,白玉兴,祁鹏,周洁珉,厉松,岐红恩.无托槽隐形矫治尖牙整体移动的生物力学研究[J].医用生物力学,2007,22(2):133-136. 被引量:21
  • 4Devocht JW, Goel VK, Zeitler DL, et al. A study of the joint using the finite element technique. J Oral Maxillofac Surg, 1996, 54: 1431 - 1437.
  • 5Storey E, Smith R. Force in orthodontics and its relation to tooth movement. Australian Journal of Orthodontics, 1952, 11.
  • 6Lee B. Relationship between tooth movement rate and estimated pressure applied. Journal of Dental Research, 1965, 4 : 1053.
  • 7Bench RW, Gugino CF, Hilgers JJ. Forces used in bioprogressive therapy. Journal of Clinical Orthodontics, 1978, 2:123.
  • 8Nikolai RJ. On optimal orthodontic force theory as applied to canine retraction. American Journal of Orthodontics, 1975, 8:290.
  • 9Yettramm AL. Center of rotation of a maxillary center incisor under orthodontic loading. Brit J Orthod, 1977,4:23.
  • 10Suhling JC, Jaeger RC. Silicon piezoresistive stress sensors and their application in electronic packaging. IEEE Sensors J, 2001, 1(1) :14-30.

共引文献32

同被引文献55

引证文献7

二级引证文献124

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部