摘要 目的:探讨国产麻醉深度检测仪与脑电双频谱指数在全身麻醉手术镇静深度监测中的相关性及安全性。方法:择期行全身麻醉手术40例,采用自身对照研究,患者入室后同时进行国产麻醉深度检测仪(记录麻醉深度指数,Cerebral State Index,CSI)与脑电双频谱指数(Bispectral Index,BIS)监测,记录麻醉诱导前(t0)、插管后3min(t1)、切皮即刻(t2)、切皮后30min(t3)、术毕(t4)、拔管时(t5)及出手术室时(t6)的CSI和BIS值(每个时点记录3组数据),并观察不良反应发生情况。结果:所有患者监测部位均未发生不良反应,各时点CSI和BIS变化一致,组间比较差异无统计学意义(P〉0.05)。结论:国产麻醉深度检测仪与BIS具有良好相关性,能较好反映围术期麻醉深度变化,使用安全可行。 Objective, To investigate the correlation and safety of domestic anesthesia depth detector with bispectral index during general anesthesia surgery sedative depth monitor. Methods. Using own control study, forty ASA grade Ⅰ or Ⅱpatients undergoing elective general anesthesia operation were included. Each one conducted with domestic anesthetic depth detector (records of Cerebral State Index, CSI) and the Bispectral Index (BIS) monitoring simultaneously. The CSI and BIS value were recorded before anesthesia induction (t0), three minutes after intubation (t1), at the beginning of the operation (t2), thirty minutes after skin incision (t3), at the end of the operation (t4), at the time of the endotracheal tube extubation (%) and, at the second of leaving the operating room (%), each time point recorded three sets of data, the adverse reactions were also observed. Results. None adverse reaction occured among all patients during the anesthesia depth monitor, changes between the CSI and BIS value were similar, and no statistical difference was observed (P〉0.05). Conclusions. The domestic anesthesia depth detector could primely reflect the perioperative anesthesia depth change, and have good correlation with BIS monitor, which can be safety use during general anesthesia.
出处 《麻醉与监护论坛》 2014年第6期459-460,共2页 Forum of Anesthesia and Monitoring
关键词 麻醉深度指数 脑电双频谱指数 镇静深度 Cerebral State Index Bispectral Index Sedative depth
  • 相关文献

参考文献2

二级参考文献24

  • 1涂学云,佘守章,许立新,闫焱,邬子林,肖颖琨.CSI与BIS指数用于监测硬膜外阻滞期间丙泊酚靶控镇静效应的比较[J].广东医学,2005,26(6):742-744. 被引量:32
  • 2潘韫丹,郭曲练,钟涛.CSI在成人靶控输注异丙酚麻醉诱导中的监测及评价[J].中南大学学报(医学版),2006,31(3):437-440. 被引量:18
  • 3Jensen EW, Litvan H, Revuelta M, et al. Cerebral state index during propofol anesthesia: a comparison with the bispectral index and the A-line ARX index. Anesthesiology, 2006, 105: 28-36.
  • 4Anderson RE, Jakobsson JG. Cerebral state monitor, a new small handheld EEG monitor for determining depth of anaesthesia: aclinical comparison with the bispectral index during day-surgery. Eur J Anaesthesio12006; 23: 208-12.
  • 5Fuentes R, Cortfnez LI, Struys MM, Delfino A, Mufioz H. The dynamic relationship between end-tidal sevoflurane concentrations, bispectralindex, and cerebral state index in children. Anesth Analg 2008; 107: 1573-8.
  • 6Hoymork SC, Hval K, Jensen EW, Raeder J. Can the cerebral state monitor replace the bispectral index in monitoring hypnotic effect during propofol/remifentanil anaesthesia? Acta Anaesthesiol Scand 2007; 51: 210-6.
  • 7Anderson RE, JakobssonJG. Cerebral state index response to incision: a clinical study in day-surgical patients. Acta Anaesthesiol Scand 2006; 50: 749-53.
  • 8Cortfnez LI, Delfino AE, Fuentes R, Munoz HR. Performance of the cerebral state index during increasing levels of propofol anesthesia:a comparison with the bispectral index. Anesth Analg 2007; 104: 605 - 10.
  • 9Jensen EW, Litvan H, Revuelta M, Rodriguez BE, Caminal P, Martinez P, et al. Cerebral state index during propofol anesthesia: a comparison with the bispectral index and the A-line ARX index. Anesthesiology 2006; 105: 28-36.
  • 10Zhong T, Guo QL, Pang YD, Peng LF, Li CL. Comparative evaluation of the cerebral state index and the bispectral index during target- controlled infusion of propofol. Br J Anaesth 2005; 95: 798-802.

共引文献25

同被引文献12

引证文献2

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部