摘要
基于溶液除湿技术,通过数值模拟,分析除湿器/再生器入口空气参数对空调机组性能及运行能耗的影响,提出溶液除湿空调在不同气候条件下的节能措施.结果表明,随着除湿器入口空气温湿度降低,吸湿溶液的流量呈非线性下降趋势,再生能力随再生器入口空气含湿量的降低而增强,所依赖的再生热源温度也随之下降.
Basing on liquid desiccant technique,through numerical modeling,this article analyzes the effect of inlet air parameter of dehumidifier/reproducer on air conditioner unit performance and operation energy consumption,presents the energy conservation measure of liquid desiccant air conditioning under different climate conditions.The result shows that with the dropping of inlet air humiture of dehumidifier,the flow of moisture absorption appears nonlinear downtrend;the regenerability will increase with the decrease of inlet air humiture of dehumidifier, the temperature of regenerating heating source it depending on decreases too.
出处
《宁夏大学学报(自然科学版)》
CAS
2014年第4期343-346,共4页
Journal of Ningxia University(Natural Science Edition)
基金
国家科技支撑计划基金资助项目(2012BAA13B02)
关键词
溶液除湿
节能
含湿量
模拟
liquid desiccant
energy conservation
moisture content
simulation