期刊文献+

共反应试剂增强电致化学发光信号生物传感器 被引量:2

Electrochemiluminescence Biosensors Based on the Signal Amplification of Co-Reactants
在线阅读 下载PDF
导出
摘要 在电致化学发光(ECL)生物传感器的构建中,利用共反应试剂促进发光基团的发光效率是一种常见、方便且非常有效的方法.然而,如何更好地利用共反应试剂使其更加有效地与发光基团作用是提高该类生物传感器灵敏度的重要因素.本文结合作者课题组部分工作综述了三种共反应试剂放大ECL信号的构建:共反应试剂内置于检测底液;共反应试剂共存于电极表面;酶促生成共反应试剂,并提出了今后ECL信号放大构建的展望. Using co-reactants to enhance the luminous efficiency of luminophores is a common, convenient and effective method in the construction of the electrochemiluminescence (ECL) biosensors. However, the different methods of introducing co-reactants in the construction of the ECL biosensors will bring different amplification effects. In this review, several signal amplification methods through co-reactants are summarized: 1) Adding the co-reactants directly into the detection solution; 2) Immobilizing the co-reactants onto the electrode surface; 3) Using enzymatic reaction to generate co-reactants in situ around the electrode surface. And then, the outlook of the ECL signal amplification strategy is proposed on those bases.
出处 《电化学》 CAS CSCD 北大核心 2015年第1期13-21,共9页 Journal of Electrochemistry
基金 国家自然科学基金项目(No.21075100 No.21105081 No.21275119)资助
关键词 电致化学发光 共反应试剂 信号放大 生物传感器 electrochemiluminescence co-reactants amplification biosensors
  • 相关文献

参考文献38

  • 1Richter M M. Electrochemiluminescence (ECL)[J]. Chemical Reviews, 2004, 104(6): 3003-3036.
  • 2Knight A W. A review of recent trends in analytical appli-cations of electrogenerated chemiluminescence [J]. TrAC Trends in Analytical Chemistry, 1999, 18(1): 47-62.
  • 3Hu L Z, Xu G B. Applications and trends in electrochemiluminescence [J]. Chemical Society Reviews, 2010, 39(8): 3275-3304.
  • 4Shi H W, Wu M S,Du Y,et al. Electrochemiluminescence aptasensor based on bipolar electrode for detection ofadensine in cancer cells [J]. Biosensors and Bioelectronics, 2014,55: 459-463.
  • 5Jiang, X Y, Chai, Y Q,Wang, H J, et al. Electrochemilu-minescence ofluminol enhanced by the synergetic catalysis of hemin and silver nanoparticles for sensitive protein de-tection[J]. Biosensors and Bioelectronics, 2014,54:20-26.
  • 6Zhang P, Wu X Y,Chai Y Q, et al. An electrochemilumi-nescent microRNA biosensor based on hybridization chain reaction coupled with hemin as the signal enhancer[J]. Analyst, 2014,149(11): 2748-2753.
  • 7Miao W J, Bard A J. Electrogenerated chemiluminescence. 77. DNA hybridization detection at high amplification with [Ru(bpy)3]奸-containing microspheres [J]. Analytical Chemistry, 2004,76(18): 5379-5386.
  • 8Zhou X M, Xing D,Zhu D B, et al. Magnetic bead and nanoparticle based electrochemiluminescence amplification assay for direct and sensitive measuring of telomerase activity [J]. Analytical Chemistry, 2009, 781(1): 255-261.
  • 9Zanarini S, Rampazzo E,Della C L,et al. Ruppy): covalently doped silica nanoparticles as multicenter tunable structures for electrochemiluminescence amplification [J]. Journal of the American Chemical Society, 2009, 131(6): 2260-2267.
  • 10Liu X Q,Shi L H, Niu W X,et al. Environmentally friendly and highly sensitive ruthenium(11) tris(2,2'-bipyridyl) electrochemiluminescent system using 2-(dibutylamino) ethanol as co-reactant [J]. Angewandte Chemie International Edition, 2007, 46(3): 421-424.

同被引文献5

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部