CT系统MTF自适应测量方法 被引量:2

A Self-Adaptive Measuring Method for MTF in CT System
在线阅读 下载PDF
导出
摘要 目的在调制传递函数(MTF)的测量中自动检测点扩展区域中心点位置,可避免手动选点的随意性及噪声对最大CT值的影响。方法根据点扩展区域是圆形的特征,通过图像处理方法分割出圆形区域,再利用数学变换的方法找出中心点位置,绘制MTF曲线。结果自动检测中心点位置的方法简化了CT系统评估的检测流程,得到了正确、稳定的中心点位置,并测得了统一的MTF曲线。结论本文提出的MTF自适应测量方法准确有效,为CT系统评估带来了方便。 Objective Implementing the automatic acquisition of central point position of point spreadregion in MTF measurement to avoid the influence of randomness and noise of manual selection on themaximum CT value. Methods According to the limitation that the shape of point spread region shouldbe roundness, to segment the point spread region with image processing methods and then identify thecentral point position with mathematical transformation methods in order to draw MTF curve. Results Thetest process of CT system evaluation has been simplified with the automatic acquisition method of centralpoint position, with which relevant staff can get the correct and stable central point position and draw thecorrect and unified MTF curve. Conclusion The proposed self-adaption measuring method for MTF isaccurate and effective, which is suitable for CT system evaluation.
出处 《中国医疗设备》 2015年第1期34-36,共3页 China Medical Devices
关键词 CT机 调制传递函数 空间分辨率 CT系统评估 CT machine modulation transfer function spatial resolution CT system evaluation
  • 相关文献

参考文献8

二级参考文献21

  • 1黄大同.CT扫描机的验收检测[J].中华放射学杂志,1994,28(9):616-619. 被引量:13
  • 2张伟,于天林.最新定位设备——多层大孔径CT模拟定位机[J].中国医学装备,2006,3(6):16-17. 被引量:4
  • 3[2]Judy PF. The line spread function and modulation transfer function of a computed tomographic scanner.Medical Physics,1976,3(4):233-236
  • 4[3]Shashadhar MM, Jeff DT, et al. Transfer function measurement and analysis for a magnetic resonance imager. Medical Physics,1991,18(6):1141-1144
  • 5[4]Michael CS, Dick JD. Frank P.Computing the modulation transfer function of a magnetic resonance imager. Medical Physics,1994,21(3):483-489
  • 6Vedantham S,Karellas A.Modeling the performance characteristics of computed radiography (CR) systems[J].IEEE Trans Med Imaging,2010,29:790-806.
  • 7Samei E,Seibert JA,Willis CE,et al.Performance evaluation of computed radiography systems[J].Med Phys,2001,28:361-371.
  • 8Yorkston J,Antonuk LE,Seraji N,et al.MTF measurements with high resolution a-Si:H imaging arrays[J].SPIE Med Imaging,1995,2432:260-269.
  • 9Samei E,Flynn MJ.A method for measuring the presampled MTF of digital radiographic systems using an edge test device[J].Med phys,1998,25:102-113.
  • 10Cunningham IA,Reid BK.Signal and noise in modulation transfer function determinations using the slit,wire,and edge techniques[J].Med Phys,1992,19:1037-1044.

共引文献29

同被引文献18

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部