摘要
本文深入研究电梯运行平均最高反向楼层数设计的理论问题。用两种方法给出了电梯运行平均最高反向楼层数公式.并用数学归纳法给出了该公式的量化计算.及该公式在各种条件下的不同表示形式,又给出了该公式的广义表示形式。这为电梯运行平均最高反向楼层数设计.对可能停站数计算,及对电梯运行周期计算准备了条件。
The paper has lucubrated for designing theory problem of the number of average highest reversal floor at elevator travel. It is given a formula of the number of average highest reversal floor by two methods, quantity calculation of its formula by the mathematical induction, different kind form of its formula under every conditions, and the broad sense of its formula. The conditions are prepared for the designing number of average highest reversal floor, for the calculating probable number of stops and for the calculation of its round trip time.
出处
《中国电梯》
2014年第22期58-61,共4页
China Elevator
关键词
平均最高反向楼层数
普阿松分布
层间交通
可能停站数
Average Highest Reversal Floor
Poisson Process
Interfloor Traffic
Probable Number of Stops