期刊文献+

转动极板技术用于600MW机组电除尘器提效改造 被引量:2

Improvement of Electrostatic Precipitator in 600 MW Unit Based on Rotating Plate Technique
在线阅读 下载PDF
导出
摘要 采用转动极板电除尘技术对北仑电厂600 MW机组电除尘器进行了设计改造,针对其存在的问题提出了解决措施,对电除尘器的前四电场内部部件进行重新设计和更换,将末电场改为转动极板电场。转动极板采用旋转刷的清灰方式,有效避免了常规电场的振打二次扬尘,提高了除尘效率,改造达到了预期的效果。 This paper introduces the rotating plate technique for 600 MW unit in Beilun power plant to transform the original dust remover,some measures are put forward to solve the problems,the first four electric field is improved,the end electric field of the dust collector is changed into a rotating plate electric field. The rotary brush cleaning of the rotating plate can effectively avoid the secondary dust and improve the efficiency of dust.
出处 《机械工程师》 2014年第11期246-248,共3页 Mechanical Engineer
关键词 电除尘 转动极板 改造 electrostatic precipitator rotating plate transformation
  • 相关文献

参考文献4

  • 1中国环保产业协会电除尘委员会.围绕“十二五”环保发展目标推进电除尘技术创新[N].中国环境报,2010-12-10(5).
  • 2孔春林,张德轩,张国文,等.转动电极式电除尘技术简介及其可靠性实验研究[J].除尘气体净化,2009(1):40-43.
  • 3Bacchiega G,Gallimberti I,Arrondel V,et al. Back-corona model for prediction of ESP efficiency and voltage-current characteristics[C]//10th International Conference on Electrostatic Precipitation, Cairns, 2006.
  • 4方辉.方芬.电场烟气流速过高对电除尘器的影响及其解决办法[c]//第12届中国电除尘学术会议论文集,2007.