期刊文献+

High sensitivity gravimetric sensor made of unidirectional carbon fiber epoxy composite on (1-x)Pb(Zn_(1/3)Nb_(2/3))O_3-xPbTiO_3 single crystal substrate

High sensitivity gravimetric sensor made of unidirectional carbon fiber epoxy composite on (1-x)Pb(Zn_(1/3)Nb_(2/3))O_3-xPbTiO_3 single crystal substrate
原文传递
导出
摘要 We have derived a general formula for sensitivity optimization of gravimetric sensors and have used it to design a high sensitivity gravimetric sensor using unidirectional carbon fiber epoxy composite (CFEC) waveguide layer on (1 -x)Pb(Znl/3Nbz/3)O3-xPbTiO3 (PZN-xPT) single crystal substrate with the carbon fibers parallel to the xj and x2 axes, respectively. The normalized maximum sensitivity (|sfm|λ)max exhibits an increasing tendency with the decrease of (h/λ)opt and the maximum sensitivity (|sfm|λ)max increases with the elastic constant c6E6 of the piezoelectric substrate material. For the CFEC/[011]c poled PZN-7%PT single crystal sensor configuration, with the carbon fibers parallel to the xa axis at λ = 24 ktm, the maximum sensitivity |sfm|max can reach as high as 1156 cmZ/g, which is about three times that of a traditional SiO2/ST quartz structure gravimetric sensor. The better design selection is to have the carbon fibers parallel to the direction of propagation of Love wave in order to obtain the best sensitivity. We have derived a general formula for sensitivity optimization of gravimetric sensors and have used it to design a high sensitivity gravimetric sensor using unidirectional carbon fiber epoxy composite (CFEC) waveguide layer on (1 -x)Pb(Znl/3Nbz/3)O3-xPbTiO3 (PZN-xPT) single crystal substrate with the carbon fibers parallel to the xj and x2 axes, respectively. The normalized maximum sensitivity (|sfm|λ)max exhibits an increasing tendency with the decrease of (h/λ)opt and the maximum sensitivity (|sfm|λ)max increases with the elastic constant c6E6 of the piezoelectric substrate material. For the CFEC/[011]c poled PZN-7%PT single crystal sensor configuration, with the carbon fibers parallel to the xa axis at λ = 24 ktm, the maximum sensitivity |sfm|max can reach as high as 1156 cmZ/g, which is about three times that of a traditional SiO2/ST quartz structure gravimetric sensor. The better design selection is to have the carbon fibers parallel to the direction of propagation of Love wave in order to obtain the best sensitivity.
出处 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第11期546-551,共6页 中国物理B(英文版)
基金 supported by the National Basic Research Program of China(Grant No.2013CB632900)
关键词 Love wave gravimetric sensor ferroelectric single crystal sensitivity optimization Love wave, gravimetric sensor, ferroelectric single crystal, sensitivity optimization
  • 相关文献

参考文献24

  • 1Tamarin O, Déjous C, Rebi'ere D, Pistré J Comeau S, Moynet D and Bezian J 2003 Sens. Actuators B 91 275.
  • 2Moreira F, Hakiki M E, Sarry F, Brizoual L L, Elmazria O and Alnot P 2007 IEEE Sensors J. 7 336.
  • 3Jakoby B and Vellekoop M J 1997 Smart Mater. Struct. 6 668.
  • 4Zadeh K K, Trinchi A, Wlodarski W and Holland A 2002 Sens. Actuators A 100 135.
  • 5Zadeh K K, Trinchi A, Wlodarski W, Chen Y Y, Fry B N and Galatsis K 2003 Sens. Actuators B 91 143.
  • 6Schlensog M D, Gronewold T M A, Tewes M, Famulok M and Quandt E 2004 Sens. Actuators B 101 308.
  • 7Wang Z, Cheeke J D N and Jen C K 1994 Appl. Phys. Lett. 64 2940.
  • 8Du J and Harding G L 1998 Sens. Actuators A 65 152.
  • 9Liu J S and He S T 2010 J. Appl. Phys. 107 073511.
  • 10Wang Y L, Zhang R, Sun E W, Song W and Cao W W 2013 Chin. Phys. Lett. 30 096301.