摘要 为实现对小尺寸箱体电磁屏蔽效能的测试,对嵌套混响室法在频率搅拌方式下的测试原理进行了分析,并从散射参数的定义出发,推导了屏蔽效能的计算方法。根据该方法,在某大型混响室内构建测试系统,利用喇叭天线与制作的单极子天线,对体积为1 m×0.8 m×0.7 m的箱体屏蔽效能进行了测试。测得的S21参数证明了频率搅拌调节场分布的有效性,而S22参数验证了混响室内测得的天线反射系数要高于其实际真值。进一步数据处理表明:屏蔽效能测试结果与天线位置的选取无关,利用改进后的屏蔽效能计算式可有效消除天线类型对测试结果的影响,这将大大提高测试的可重复性。 In order to test the shielding efficiency(SE) of small cavity, we investigated the principle of nested frequen- cy-stirred reverberation chamber test method, and deduced a calculation method of SE based on the definition of scattering parameters. According to this method, we built an SE testing system in a big reverberation chamber, and then measured the SE of a small enclosure of 1 m×0.8 m×0.7 m using horn and monopole antennas. According to the obtained S21, the frequency stirring mode is effective on changing the electromagnetic field. The measured S22 shows that the tested antenna reflection coefficient in the reverberation chamber is always higher than its true value. Further processing of the data shows that the test result is independent of the location of receiving antennas. Additionally, the improved SE calculation can eliminate the influence from antenna type, which greatly improves repeatability of the test method.
出处 《高电压技术》 EI CAS CSCD 北大核心 2014年第9期2699-2705,共7页 High Voltage Engineering
基金 国家自然科学基金(51107147 51177174)~~
关键词 混响室 屏蔽效能 小尺寸箱体 嵌套混响室 频率搅拌 散射参数 reverberation chamber shielding effectiveness small enclosure nested reverberation chamber frequencystirring scattering parameter
  • 相关文献

参考文献22

二级参考文献87

  • 1袁智勇,何金良,曾嵘,陈水明.电磁兼容试验中的混响室技术[J].高电压技术,2005,31(3):56-57. 被引量:25
  • 2丁坚进,沙斐.EMC混响室电磁场模态研究[J].电波科学学报,2005,20(5):557-560. 被引量:16
  • 3周香,蒋全兴,王文进.搅拌器配置对混波室独立采样点的影响[J].电波科学学报,2005,20(6):802-805. 被引量:4
  • 4Benhassine S, Pichon L. An efficient finite element time-domain method for the analysis of the coupling between wave and shielded enclosure[J].IEEE Transaction on Magnetics,2002, 38(2):709-712.
  • 5Robinson M P, Benson T M, Christopoulos C D, et al. Analytical formulation for the shielding effectiveness of enclosures with apertures[J]. IEEE Trans on Electromagnetic Compatibility, 1998,40(8) : 240 -248.
  • 6Belokour I, LoVetri J, Kashyap S. A higher order mode transmission line model of the shielding effectiveness of enclosures with apertures [C]//2001 EMC IEEE International Symposium Proceedings. 2001:702-707.
  • 7Cerri G, Leo R De,Primiani M. Theoretical and experimental evaluation of the electromagnetic radiation from apertures in shielded enclosures[J]. IEEE Trans on Electromagnetic Compatibility, 1992,34(11):423-432.
  • 8Wallyn W. Prediction of the shield and resonant behavior of multisection enclosure based on magnetic current modeling[J].IEEE Transac tion on Electromagnetic Compatibility, 2002,44 (1) : 295-304.
  • 9MIYATA S,KAYANO Y,INOUE H.EM radiation through aperture of metallic enclosure with a PCB inside[Z].AsiaPacific Symposium on EMC,Singapore,2008.
  • 10GU Chunhong.Shielding effectiveness of an enclosure with apertures[Z].IEEE 2005 International Symposium on Microwave,Antenna,Propagation and EMC Technologies for Wireless Communications,Beijing,2005.

共引文献49

同被引文献48

  • 1徐加征,蒋全兴,王巍.直接电流注入在电磁兼容中的频率应用范围[J].电波科学学报,2006,21(4):488-491. 被引量:16
  • 2郎为民,姜斌,张云峰,等.电磁屏蔽原理与应用[M].北京:机械工业出版社,2009:1-9.
  • 3程二威.混响室内尺寸屏蔽体屏蔽效能测试方法与实验研究[D].石家庄:军械工程学院,2009:14-15.
  • 4卢新福,魏光辉,潘晓东.等效强场辐射敏感度的双端差模电流注入方法[J].高电压技术,2013,39(10):2431-2437.
  • 5军用设备和分系统电磁发射和敏感度要求与测量:GJBl51B-2013[S],2013.
  • 6Corona P, Ladbury J, Latmiral C. Reverberation-chamber re- search-then and now: a review of early work and comparison with current understanding[J]. IEEE Transactions on Electromagnetic Compatibility, 2002, 44(1): 87-94.
  • 7Hoijer M, Backstr6m M. How we confused the comparison between high level radiated susceptibility measurements in the reverberation chamber and at the open area test site[C]//IEEE Symposium on Elec- tromagnetic Compatibility. Istanbul, Turkey: IEEE, 2003:1043-1046.
  • 8Freyer G J, Backstr6m M G, Comparison of anechoic & reverberation chamber coupling data as a function of directivity pattern-Part II [C] //IEEE Symposium on Electromagnetic Compatibility. Montreal, Canada: IEEE, 2001:286-291.
  • 9Borgstrom E J. A comparison of methods and results using the semi-anechoic and reverberation chamber radiated RF susceptibility test procedures in RTCA/DO-160D, Change One[C]//IEEE Sympo- sium on Electromagnetic Compatibility. Silicon Valley, USA: IEEE, 2002: 184-188.
  • 10Tsigros C, Piette M, Vandenbosch G A E, et al. Radiated immunity in reverberation and semianechoic rooms: conditions for equivalence[J]. IEEE Transactions on Electromagnetic Compatibility, 2013, 55(2): 222-230.

引证文献4

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部