期刊文献+

微测辐射热计的热隔离结构设计 被引量:1

Design of Thermal Isolation Structure for Microbolometer
在线阅读 下载PDF
导出
摘要 推导了微测辐射热计热隔离结构的热量模型 ,对系统热响应时间和响应率之间的关系进行了分析 ,在满足系统响应要求下对热隔离结构的热量参数的确定进行了理论分析和探讨 ,热量参数曲线图提供了直观的参考 。 The thermal model of thermal isolation structure for microbolometer is deduced and the relationship between system response time and responsibility is analyzed.The definition of thermal parameter of thermal isolation structure with requirement for meeting system response is made analysis and discussed,curve plots for thermal parameters can provide vertical referrence.The paper also presented schemes on optimal design of thermal parameters conbined practise.
出处 《激光与红外》 CAS CSCD 北大核心 2002年第4期265-267,共3页 Laser & Infrared
关键词 微测辐射热计 热隔离结构 热导 热容 microbolometer thermal isolation structure thermal conductance heat capacity
  • 相关文献

参考文献2

共引文献6

同被引文献8

  • 1Knappe S,Schwindt P D D,Shah V,et al.A chip-scale atomicclock based on 87Rb with improved frequency stability[J].Op-tics Express,2005,13(4):1249-1253.
  • 2Xu Lei,Li Tie,Gao Xiuli,et al.Development of a reliable micro-hotplate with low power consumption[J].IEEE Sensors Journal,2011,11(4):913-919.
  • 3Lutwak R,Deng J,Riley W,et al.The CSAC low-power physicspackage [C]//36th Annual Precise Time and Time Interval(PT-TI)Meeting,Washington DC,2004 ;339-354.
  • 4Mescher M,Lutwak R,Varghese M.An ultra-low-power physicspackage for a chip-scale atomic clock[J].The Draper Technolo-gy Digest,2005,10;26-31.
  • 5Bao Minhang.Analysis and design principles of MEMS device-s[M],Shanghai:Elsevier,2004;52-55.
  • 6Chutani R K,Galliou S,Passilly N,et al.Thermal management offully LTCC-packaged Cs vapour cell for MEMS atomic clock [J].Sensors and Actuators A:Physical,2012,174:58-68.
  • 7施芹,丁荣峥,苏岩,裘安萍.硅微陀螺仪器件级真空封装[J].机械工程学报,2009,45(2):243-246. 被引量:5
  • 8刘亦敏,聂金泉,赵玉龙,彭年才.一种微腔型PCR集成芯片的设计及其热分析[J].传感技术学报,2011,24(8):1092-1097. 被引量:2

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...