摘要
目的观察一种隐形眼镜护理液抑菌性能及其使用持续时间。方法采用ISO 14730-2000和USP 35<51>规定的两种方法,对该隐形眼镜护理液的抑菌性能进行观察,比较ISO和USP两种方法试验结果的差异性。结果按照USP 35<51>方法,该隐形眼镜护理液在启用后第7、14和28 d,各试验菌减少量均符合要求。按照ISO14730:2000方法,该隐形眼镜护理液在启用后第14 d,各试验菌减少量均符合要求,第28 d各试验菌减少量均不符合ISO要求。结论应根据产品用途、有效期、预期的抑菌发生速度及维持时间建立合理的试验方案。
Objective To observe the antimicrobial efficacy and its duration of one kind of contact lens care solution. Methods The methods of ISO 14730 - 2000 and USP 35 〈 51 〉 were used to validate the antimicrobial efficacy and compare the difference between the results of the solution. Result According to the method of USP 35 〈 51 〉 , the count at the 7^th day, 14^th day and 28^th day all met the criteria. According to the method of ISO 14730 -2000, the count at the 14^th day met the criteria and not of the 28^th day's count. Conclusion The usage, expireation date, and the expectant antimicrobial speed and the duration of the antimicrobial efficacy help to make a reasonable test protocol.
出处
《中国消毒学杂志》
CAS
北大核心
2014年第7期680-682,共3页
Chinese Journal of Disinfection
关键词
隐形眼镜
护理液
抑菌性能
验证方法
国际标准
contact lens
care solution
antimicrobial efficacy
validation method
international standard