摘要 研究相邻两面受火情况下钢骨-方钢管混凝土柱截面温度场分布,设计了钢骨-方钢管柱在ISO-834标准升温情况下的温度场试验,运用有限元分析软件ANSYS建立模型,与试验结果比较,验证模型和计算程序的可靠性.研究表明,与四面受火下截面温度分布形式相比,相邻两面受火下截面温度整体偏低,材料损伤相对较轻,但截面温度近似沿对角线对称分布,这种分布会导致初始挠度与附加的偏心距.在工程常用范围内,分析了多个参数对钢骨-方钢管混凝土截面温度场的影响规律,结果表明,升温时间和截面边长对截面温度场分布影响较大.研究可为相邻两面受火情况下钢骨-方钢管混凝土柱的设计和耐火性能分析提供理论基础. A test was done and a numerical model was established with the software ANSYS to study the temperature distribution in square steel tubes filled with steel reinforced concrete under adjacent two-sided fires. The reliability of the approach was validated by the good agreement between the theoretical results and the experimental data at elevated temperature. The temperature distributions of the square cross-sections in adjacent two-sided and four-sided fires were analyzed based on the numerical model, and the results indicate that the cross-sectional temperature in a two-sided fire is lower and the material deterioration is slighter than that in a four-sided fire. The cross-sectional temperature distribution is approximately diagonal and symmetrical in an adjacent two-sided fire. Consequently, it leads to initial deflection and additional load eccentricity. The effects of parameters on the cross-sectional temperature distribution of square steel tubes filled with steel reinforced concrete (CFSTs) were analyzed. The results show that the exposure time and size of the cross section have significant effects on the temperature distribution of CFSTs. The results will provide theoretical basis for analysis of adjacent two-sided fire resistance performance and fire design of CFSTs.
出处 《深圳大学学报(理工版)》 EI CAS 北大核心 2014年第4期402-409,共8页 Journal of Shenzhen University(Science and Engineering)
基金 上海市自然科学基金资助项目(11ZR1426400)~~
关键词 结构工程 组合构件 钢管混凝土柱 structural engineering composite member steel tube filled with concrete temperature distribution two-side fire finite element analysis
  • 相关文献

参考文献20

  • 1朱美春,刘建新,王清湘.钢骨-方钢管高强混凝土柱的轴压比限值[J].深圳大学学报(理工版),2010,27(1):95-102. 被引量:6
  • 2王清湘,朱美春,冯秀峰.型钢-方钢管自密实高强混凝土轴压短柱受力性能的试验研究[J].建筑结构学报,2005,26(4):27-31. 被引量:23
  • 3王连广,刘晓,常江.钢管钢骨高强混凝土偏心受压承载力试验研究[J].工程力学,2010,27(2):124-129. 被引量:13
  • 4韩林海,杨有福,霍静思.钢管混凝土柱火灾后剩余承载力的试验研究[J].工程力学,2001,18(6):100-109. 被引量:32
  • 5Lie T T, Stringer D C. Calculation of the fire resistance ofsteel hollow structural section columns filled with plain concrete [ J ]. Canadian Journal of Civil Engineering, 1994, 21(3): 382-385.
  • 6Lie T T, Chabot M. Experimental studies on the fire re- sistance of hollow steel columns filled with plain concrete [R]. No. 611. Ottawa (Ontario): National Research Council of Canada, Institute for Research in Construction, 1992.
  • 7Yang Hua, Han Linhai, Wang Yongchang. Effects of heating and loading histories on post-fire cooling behavior of concrete-filled steel tubular columns [ J]. Journal of Constructional Steel Research, 2008, 64 (5) : 556-570.
  • 8Han L H, Chen F, Liao F Y, et al. Fire performance of concrete filled stainless steel tubular columns [ J ]. Engi- neering Structures, 2013, 56(5) : 165-181.
  • 9Wang K, Young B. Fire resistance of concrete-filled high strength steel tubular columns [ J ]. Thin-Walled Struc- tures, 2013, 71(5): 46-56.
  • 10Erdil B, Akyuz U, Yaman I O. Mechanical behavior of CFRP confined low strength concretes subjected to simulta- neous heating-cooling cycles and sustained loading [ J ]. Materials and Structures, 2012, 45 (1/2) : 223-233.

二级参考文献50

共引文献113

同被引文献16

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部