溶解氧的快速现场测定 被引量:10

In situ Determination of the Dissolved Oxygen in Water
在线阅读 下载PDF
导出
摘要 The indigo carmine was reduced by using cheap,easily attainable and non poisonous reagents. Therefore, a special reagent was developed to measure the concentration of dissolved oxygen in water in situ . The molar absorption coefficient of the method is 1 35×10 4, and its dynamic linear range is 0-27 mg/L linearity coefficient of 0 997. The most oxidizing species, such as Cl 2, ClO -, Cu 2+ , Fe 3+ , V 5+ , and As(Ⅴ), do not interfere the determination. It takes no more than 1 min to analyze one sample. The method was applied to determining some practical samples and all the results obtained were satisfactory. The indigo carmine was reduced by using cheap,easily attainable and non poisonous reagents. Therefore, a special reagent was developed to measure the concentration of dissolved oxygen in water in situ . The molar absorption coefficient of the method is 1 35×10 4, and its dynamic linear range is 0-27 mg/L linearity coefficient of 0 997. The most oxidizing species, such as Cl 2, ClO -, Cu 2+ , Fe 3+ , V 5+ , and As(Ⅴ), do not interfere the determination. It takes no more than 1 min to analyze one sample. The method was applied to determining some practical samples and all the results obtained were satisfactory.
出处 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2002年第8期1501-1503,共3页 Chemical Journal of Chinese Universities
基金 吉林省科技发展项目 (批准号 :93 10 0 8)资助
关键词 溶解氧 现场测定 手持式光度计 水体污染 环境监测 Dissolved oxygen In situ determination Portable photometer
  • 相关文献

参考文献16

  • 1The National Environment Protection Bureau. The Methods for Inspecting and Analyzing Water and Waste Water, 3rd Ed.(水和废水监测分析方法, 第三版)[M], Beijing: Chinese Environmental Science Publishing Company, 1989: 246-252
  • 2Peeters F., Kipfer R., Achermann D.et al..Deep-Sea Research[M], 2000, 47(4A): 621-654
  • 3Anthony V., Abolfazl Fiacco. Operations Research[M], 1982, 30(1): 1-28
  • 4Donna I., Barbara L., Harry A.. J. Bio. Cycle[J], 1992, 33(11): 62-66
  • 5OSullivana D. W., Hanson A. K., Kesterb D. R.. Coastal and Shelf Science[J], 1997, 45(6): 769-788
  • 6O′Riordan T. C., Buckley O., Ogurtsov V.et al..Analytical Biochemistry[J], 2000, 278(2): 221-227
  • 7Hitchman M. L.. Measurement of Dissolved Oxygen[M], New York: John Wiley and Sons, 1978: 160-169
  • 8Hitchman M. L.. Measurement of Dissolved Oxygen[M], New York: John Wiley and Sons, 1978: 71-129
  • 9Clark L. C.. U.S. Patent, 2 913 386[P], 1959
  • 10陈焕文,于爱民,韩松柏,李双峰,金钦汉.手持式测碘仪[J].分析仪器,2000(4):28-30. 被引量:3

二级参考文献5

共引文献11

同被引文献175

引证文献10

二级引证文献111

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部